Physical function, gait, and dynamic balance of transfemoral amputees using two mechanical passive prosthetic knee devices.

机译:使用两个机械式被动假肢膝关节器械,经股截肢者的身体功能,步态和动态平衡。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: To investigate the effect of the 3R90 and 3R92 (Otto Bock Healthcare) mechanical passive prosthetic knee devices on the physical function, gait, and dynamic balance (sudden stop and turn) of transfemoral amputees. DESIGN: Intervention study with crossover design. SETTING: University research center. PARTICIPANTS: Men (N=5; mean age +/- SD, 58.8+/-11.9y) with unilateral transfemoral amputation. INTERVENTION: Prosthetic knee joints (N=2; 3R90 and 3R92). Acclimatization ranged from 14 to 47 days (25.5+/-9.3d). MAIN OUTCOME MEASURES: Physical function, gait, dynamic balance. RESULTS: The Timed Up and Go Test, 6-Minute Walk Test, and Four Square Step Test measures improved with the 3R92. Total scores on the Prosthesis Evaluation Questionnaire were similar for the 3R92 (82.0+/-6.3) and the participant's own or original device (83.9+/-4.8). These devices were rated higher than the 3R90 (65.5+/-16.8). Compared with the original device, gait velocity was significantly slower (5cm/s; P=.017) with the 3R92, but was unchanged for the 3R90. This difference was not considered clinically significant because the effect size was small (0.2). No other significant gait differences were found. Large temporal gait asymmetries observed with the original device remained with the 3R90 and 3R92 (step, approximately 20%; single support, approximately 30%; stance, approximately 19%). Although no significant differences were found for the sudden-turn or sudden-stop tasks, the sudden-turn group success rates were highest with the original devices. CONCLUSIONS: Gait and symmetry measures were unchanged. Gait speed was slower with the 3R92, but this was not considered to be clinically significant. Sudden-turn success rates generally were higher with the original devices. A crossover stepping movement was more difficult to implement than a side-stepping movement during sudden turns.
机译:目的:研究3R90和3R92(Otto Bock Healthcare)机械式被动假肢膝关节装置对经股截肢者的身体功能,步态和动态平衡(突然停止和转弯)的影响。设计:采用交叉设计的干预研究。地点:大学研究中心。参与者:男性(N = 5;平均年龄+/- SD,58.8 +/- 11.9y),单侧经股骨截肢。干预:假肢膝关节(N = 2; 3R90和3R92)。适应时间为14到47天(25.5 +/- 9.3天)。主要观察指标:身体机能,步态,动态平衡。结果:3R92改进了定时起跑测试,6分钟步行测试和四步走步测试。假体评估问卷的总分与3R92(82.0 +/- 6.3)和参与者自己的或原始设备(83.9 +/- 4.8)相似。这些设备的额定值高于3R90(65.5 +/- 16.8)。与原始设备相比,使用3R92的步态速度明显较慢(5cm / s; P = .017),但对于3R90则没有变化。由于效果大小较小(0.2),因此该差异不被认为具有临床意义。没有发现其他明显的步态差异。 3R90和3R92在原始设备上观察到的较大的步态不对称性(步长约为20%;单支撑位约为30%;姿势约为19%)。尽管对于急转弯或急停任务没有发现显着差异,但在原始设备上,急转弯组的成功率最高。结论:步态和对称性措施均未改变。 3R92的步态速度较慢,但​​这在临床上并不重要。原始设备的转弯成功率通常较高。在突然转弯时,跨步运动比侧步运动更难实施。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号