Evaluation of liver iron content using synchrotron radiation CT in iron-overload mice

机译:使用同步加速器评价肝脏铁含量铁过量的辐射CT老鼠

获取原文
获取原文并翻译 | 示例
           

摘要

Evaluation of liver iron content (LIC) is crucial for the judgment of hepatic iron overload (HIO). Here, we evaluated the potential utility of synchrotron radiation (SR) CT for quantifying LIC in mice suffered from HIO. The mice models of HIO were made by the injection of iron dextran. A series of total iron injection doses of 0, 12.5, 25, 50 and 100 mg were used. SR CT imaging was performed using a detector with the pixel size of 6.5 μm ×6.5 μm at the energy level of 12 keV. The iron micro-depositions were pathologically confirmed using Prussian blue staining. The reconstructed transverse sections were obtained by applying the filtered back projection (FBP) algorithm with PITRE software. 3D visualization was performed using Amira 5.4. LIC was confirmed by an inductively coupled plasma (ICP) spectrometer. SR CT-derived LIC (LICCT) was defined as the volume ratio of iron depositions to the liver. The volume ratio was measured using ImageJ software. SR CT presented a high-spatial resolution to clearly display iron micro-depositions in the iron-overload liver. Additionally, iron micro-depositions were found to distribute unevenly on 3D images. The LICCTs were 0, (1.890 ± 0.172), (4.148 ± 0.282), (6.769 ± 0.201), and (12.912 ± 0.270) for injection doses of 0 mg, 12.5 mg, 25 mg, 50 mg and 100 mg, respectively. LICCT had a strong linear correlation with injection dose (R~2 = 0.9930, P < 0.0001) or ICP-derived LIC (LIC_(ICP)) (R~2 = 0.9644, P < 0.0001). The linear correlation between LICCT and LIC_(ICP) could be expressed by an equation. Using this equation, LIC could be predicted by measuring LICCT. Therefore, SR CT imaging showed potential ability to quantify LIC. The imaging modality may be used for the evaluation of disease progression and therapeutic efficacy in mice models.
机译:评价肝脏铁含量(LIC)是至关重要的肝铁过载的判断(HIO)。在这里,我们评估的潜在效用同步辐射(SR) CT定量地方政府投资公司在老鼠遭受HIO。是由右旋糖酐铁的注入。一系列的总铁注入剂量的0,12.5,25、50和100毫克。执行使用探测器的像素大小6.5μm×6.5μm 12 keV能量级别的。铁micro-depositions是病态确认使用普鲁士蓝染色。重建的横截面通过应用过滤后投影(FBP)算法与PITRE软件。使用阿米拉5.4执行。由一个电感耦合等离子体(ICP)谱仪。定义为体积比的铁口供到肝脏。ImageJ软件。清楚地显示铁的决心micro-depositions铁超负荷的肝脏。此外,铁micro-depositions被发现在3 d图像分配不均。注射剂量的0 mg, 12.5毫克,25毫克,50毫克和100毫克。线性相关与注入剂量(R ~ 2 =0.9930, P < 0.0001)或ICP-derived地方政府投资公司(LIC_ (ICP)) (R ~ 2 = 0.9644, P < 0.0001)。线性相关性LICCT和LIC_ (ICP)可以由一个方程表示。预测方程,地方政府投资公司可以通过测量LICCT。量化地方政府投资公司的能力。被用于评估疾病进展和小鼠的治疗效果模型。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号