...
首页> 外文期刊>Antimicrobial agents and chemotherapy. >In vitro pharmacodynamic evaluation of the mutant selection window hypothesis using four fluoroquinolones against Staphylococcus aureus.
【24h】

In vitro pharmacodynamic evaluation of the mutant selection window hypothesis using four fluoroquinolones against Staphylococcus aureus.

机译:使用四个氟喹诺酮类药物对金黄色葡萄球菌的突变选择窗口假说的体外药效学评估。

获取原文
获取原文并翻译 | 示例
           

摘要

To study the hypothesis of the mutant selection window (MSW) in a pharmacodynamic context, the susceptibility of a clinical isolate of methicillin-resistant Staphylococcus aureus exposed to moxifloxacin (MOX), gatifloxacin (GAT), levofloxacin (LEV), and ciprofloxacin (CIP) was tested daily by using an in vitro dynamic model that simulates human pharmacokinetics. A series of monoexponential pharmacokinetic profiles that mimic once-daily administration of MOX (half-life, 12 h), GAT (half-life, 7 h), and LEV (half-life, 6.8 h) and twice-daily administration of CIP (half-life, 4 h) provided peak concentrations (C(max)) that either equaled the MIC, fell between the MIC and the mutant prevention concentration (MPC) (i.e., within or "inside" the MSW), or exceeded the MPC. The respective ratios of the area under the curve (AUC) over a 24-h dosing interval (AUC(24)) to the MIC varied from 13 to 244 h, and the starting inoculum was 10(8) CFU/ml (6 x 10(9) CFU per 60-ml central compartment). With all four quinolones, the greatest increases in MIC were observed at those AUC(24)/MIC values (from 24 to 62 h) that corresponded to quinolone concentrations within the MSW over most of the dosing interval (>20%). Less-pronounced increases in MIC were associated with the smallest simulated AUC(24)/MIC values (15 to 16 h) of GAT and CIP, whose C(max) exceeded the MICs. No such increases were observed with the smallest AUC(24)/MIC values (13 to 17 h) of MOX and LEV, whose C(max) were close to the MICs. Also, less pronounced but significant increases in MIC occurred at AUC(24)/MIC values (107 to 123 h) that correspond to quinolone concentrations partly overlapping the MIC-to-MPC range. With all four drugs, no change in MIC was seen at the highest AUC(24)/MIC values (201 to 244 h), where quinolone concentrations exceeded the MPC over most of the dosing interval. These "protective" AUC(24)/MIC ratios correspond to 66% of the usual clinical dose of MOX (400 mg), 190% of a 400-mg dose of GAT, 220% of a 500-mg dose of LEV, and420% of two 500-mg doses of CIP. Thus, MOX may protect against resistance development at subtherapeutic doses, whereas GAT, LEV, and CIP provide similar effects only at doses that exceed their usual clinical doses. These data support the concept that resistant mutants are selectively enriched when antibiotic concentrations fall inside the MSW and suggest that in vitro dynamic models can be used to predict the relative abilities of quinolones to prevent mutant selection.
机译:为了研究在药效学背景下突变选择窗口(MSW)的假设,对暴露于莫西沙星(MOX),加替沙星(GAT),左氧氟沙星(LEV)和环丙沙星(CIP)的耐甲氧西林金黄色葡萄球菌临床分离株的敏感性每天使用模拟人体药物动力学的体外动力学模型进行测试。一系列模拟MOX(半衰期,12 h),GAT(半衰期,7 h)和LEV(半衰期,6.8 h)每天一次给药和CIP每天两次给药的单指数药代动力学曲线(半衰期4小时)提供的峰值浓度(C(max))等于MIC,介于MIC和突变预防浓度(MPC)之间(即,MSW内或之内),或超过了MPC。在24小时的给药间隔(AUC(24))与MIC的曲线下面积(AUC)的比值从13到244 h不等,起始接种量为10(8)CFU / ml(6 x每60毫升中央隔室10(9)CFU)。对于所有四种喹诺酮类药物,在大多数给药间隔(> 20%)内,对应于MSW中喹诺酮浓度的AUC(24)/ MIC值(24至62 h)观察到MIC的最大增加。 MIC的不那么明显的增加与GAT和CIP的最小模拟AUC(24)/ MIC值(15至16小时)相关,其C(max)超过了MIC。 MOX和LEV的最小AUC(24)/ MIC值(13至17小时)没有观察到这种增加,其C(max)接近MIC。另外,在AUC(24)/ MIC值(107至123小时)处,MIC的增加并不明显,但显着增加,这对应于喹诺酮浓度部分重叠了MIC-MPC范围。对于所有四种药物,在最高AUC(24)/ MIC值(201至244小时)时,MIC均未见变化,其中喹诺酮浓度在大多数给药间隔内超过了MPC。这些“保护性” AUC(24)/ MIC比例分别相当于常规临床剂量的MOX(400 mg)的66%,400 mg的GAT剂量的190%,500 mg的LEV剂量的220%两个500毫克CIP剂量的百分比。因此,MOX可以在亚治疗剂量下抵抗耐药性的发展,而GAT,LEV和CIP仅在超过其常规临床剂量的剂量下才能提供类似的作用。这些数据支持这样的概念,即当抗生素浓度落在城市固体废弃物内时,选择性地富集了抗性突变体,并表明体外动态模型可用于预测喹诺酮类药物防止突变体选择的相对能力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号