首页> 外文期刊>Applied radiation and isotopes: including data, instrumentation and methods for use in agriculture, industry and medicine >Activity standardisation of F-18 and ionisation chamber calibration for nuclear medicine
【24h】

Activity standardisation of F-18 and ionisation chamber calibration for nuclear medicine

机译:F-18的活动标准化和核医学的电离室校准

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Primary activity standardisations were performed on solutions of F-18 using 4 pi beta-y coincidence counting and liquid scintillation counting (LSC) according to the CIEMAT/NIST method. A beta(+)-emission probability of 96.86% was used for both methods. The various standardised F-18 solutions were measured in ionisation chambers of the Physikalisch-Technische Bundesanstalt (PTB) and compared by determining radionuclide calibration factors. Already in 2001 an F-18 solution had been standardised at the PTB and compared with the results of nine national metrology institutes (NMIs), using the ISOCAL IV secondary radionuclide calibrators of the National Physical Laboratory (NPL) as transfer instruments and a Ge-68 check source solution. These results were linked to the International Reference System (SIR) at the Bureau International des Poids et Mesures (BIPM) by aliquots of solutions sent by the Laboratoire National Henri Becquerel (BNM-LNHB) and the NPL. Further on, in 2005, PTB sent an aliquot of an F-18 solution to the SIR for ionisation chamber measurements. A value of the equivalent activity was determined and included in the key comparison database (KCDB). The recent PTB value of the equivalent activity of the SIR is in good agreement with the key comparison reference value determined from five NMIs. These results confirm that the standardisation of F-18 solutions can be achieved with the accuracy required for use in nuclear medicine and, in particular, for applications in positron emission tomography (PET). (c) 2007 Elsevier Ltd. All rights reserved.
机译:根据CIEMAT / NIST方法,使用4 pi beta-y符合计数和液体闪烁计数(LSC)对F-18溶液进行主要活性标准化。两种方法均使用96.86%的beta(+)发射概率。在Physikalisch-Technische Bundesanstalt(PTB)的电离室中测量了各种标准化的F-18溶液,并通过确定放射性核素校准因子进行了比较。在2001年,PTB已将F-18解决方案标准化,并与9个国家计量机构(NMI)的结果进行了比较,使用国家物理实验室(NPL)的ISOCAL IV二次放射性核素校准器作为传输仪器,并使用了Ge- 68检查源解决方案。这些结果通过国家实验室亨利·贝克勒尔(BNM-LNHB)和NPL发送的解决方案等分试样与国际纸币和测量机构(BIPM)的国际参考系统(SIR)相关联。随后,在2005年,PTB向SIR发送了一份F-18溶液的等分试样,用于电离室测量。确定了等效活动的值,并将其包括在密钥比较数据库(KCDB)中。 SIR等效活动的最新PTB值与从五个NMI确定的关键比较参考值非常吻合。这些结果证实,F-18解决方案的标准化可以以核医学特别是正电子发射断层扫描(PET)应用所需的精度实现。 (c)2007 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号