In this work, concentrations of silicon, aluminium and magnesium in geological matrices were determined by Neutron Activation Analysis based on k0-IAEA software. The optimum activation and delay times were found to be 5min and 15-20min respectively for the determination of Si via 29Si (n,p) 29Al reaction. The adopted irradiation scheme did not work for the determination of magnesium. Each sample was irradiated under a thermal neutron flux density of 5.0×1011ncm-2s-1. Cadmium covered activation indicated that a permanent epithermal irradiation site for research reactors would be very useful for routine determination of silicon in environmental samples.
机译:在这项工作中,通过基于k0-IAEA软件的中子活化分析确定了地质基质中硅,铝和镁的浓度。发现通过29Si(n,p)29Al反应确定Si的最佳活化时间和延迟时间分别为5min和15-20min。所采用的辐照方案不适用于测定镁。在5.0×1011ncm-2s-1的热中子通量密度下照射每个样品。镉覆盖的活化作用表明,研究堆的永久性超热辐射位点对于常规测定环境样品中的硅非常有用。