首页> 外文期刊>Applied radiation and isotopes: including data, instrumentation and methods for use in agriculture, industry and medicine >DETERMINATION OF SPECTRAL EMISSION OF TUNGSTEN TARGET TUBES MEASURING X-RAY FLUORESCENCE FROM PURE ELEMENTS
【24h】

DETERMINATION OF SPECTRAL EMISSION OF TUNGSTEN TARGET TUBES MEASURING X-RAY FLUORESCENCE FROM PURE ELEMENTS

机译:从纯元素中测定测量X射线荧光的钨靶管的光谱发射

获取原文
获取原文并翻译 | 示例

摘要

Accurate knowledge of the spectral emission from an x-ray tube has been a problem of permanent concern during recent decades. Different areas of physics such as x-ray fluorescence spectrometry, medical physics studies etc. require tabulated spectral data. Several techniques and methods have been proposed in the past to solve this problem. In this work we propose an indirect method of x-ray spectrum determination by measuring fluorescent intensities from pure elements. The main aspect of this proposal is that no changes of the spectrometer are required, such as tube removal or disassembly of the sample chamber.
机译:近几十年来,对来自X射线管的光谱发射的准确了解一直是人们一直关注的问题。诸如X射线荧光光谱法,医学物理学研究等物理领域的不同领域都需要列表化的光谱数据。过去已经提出了几种技术和方法来解决该问题。在这项工作中,我们提出了一种通过测量纯元素的荧光强度来间接确定X射线光谱的方法。该提议的主要方面是不需要光谱仪的任何改变,例如管子的拆卸或样品室的拆卸。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信