The impedance match is important for the efficiency and available acoustic power of thermocompressor (TCP). The filling pressure, hot end temperature, reservoir volume and opening of orifice were changed to test the optimum load impedance for the maximum acoustic power by RC (Resistor and Capacitor) load method. To make use of the acoustic power efficiently, a pulse tube refrigerator (PTR) was designed based on this impedance to match the TCP and relative coupling experiments were conducted for the first time. The refrigerating performance of PTR was observed and the lowest no-load temperature of 70.4 K was obtained at its optimum working frequency 5.6 Hz. Also, the performance characteristics and total impedances of three different PTRs were compared to verify the rationality of the impedance matching method in this paper. The calculation results agree well with the substantial experiments and further optimization methods were also proposed.
机译:阻抗匹配对于热压缩机(TCP)的效率和可用声功率很重要。改变填充压力,热端温度,容器容积和孔口,以通过RC(电阻和电容)负载法测试最大声功率的最佳负载阻抗。为了有效地利用声功率,基于此阻抗设计了脉冲管制冷机(PTR)以匹配TCP,并且首次进行了相对耦合实验。观察到PTR的制冷性能,在其最佳工作频率5.6 Hz时,最低空载温度为70.4K。此外,比较了三种不同PTR的性能特征和总阻抗,以验证本文阻抗匹配方法的合理性。计算结果与实际实验吻合良好,并提出了进一步的优化方法。