摘要

TRT has been a useful and consolidated tool to determine the ground thermal properties for GSHP. In this paper, six TRTs were carried out to analyze the heat transfer performance of GHE based on constant temperature and heat-flux methods. Vertical temperatures were measured using temperature sensors installed along GHE pipes. A multi-layer cylindrical source model was developed to estimate thermal conductivity distributions in the ground around GHE based on the vertical temperatures. The results showed that the constant temperature method had many advantages in shortening test period, operating stability and test accuracy compared with the traditional constant heat-flux method. The estimated thermal conductivities obtained based on the multi-layer cylindrical source model were consistent with the geological conditions and groundwater aquifer. (C) 2015 Elsevier Ltd. All rights reserved.
机译:TRT是确定GSHP地热特性的有用且综合的工具。本文采用恒温和热通量方法,通过六个TRTs来分析GHE的传热性能。使用沿GHE管道安装的温度传感器测量垂直温度。建立了多层圆柱源模型,以基于垂直温度估算GHE周围地面的热导率分布。结果表明,与传统的恒温热通量法相比,恒温法在缩短测试周期,操作稳定性和测试精度方面具有许多优势。基于多层圆柱源模型获得的估算热导率与地质条件和地下水含水层一致。 (C)2015 Elsevier Ltd.保留所有权利。