A novel cold plate for cooling of the electronic components with high heat flux and high heat dissipation requirements is proposed. The cold-plate structure of the S-type with guide plates is introduced to avoid the heat hot concentration and increase the heat transfer area. The experimental results show that the maximum chip temperature of the novel cold plate is approximately 40% lower than those of the conventional cold plate. Thermal performance optimizations are conducted, indicating that it is extremely effective to install the heat source on two sides of the cold plate. Compared with the single-side heat source, the maximum chip temperature is increased only 20%. However, the heat dissipation is doubled in the limited space for the double-sides arrangement heat source. Moreover, the integrated density of the power module is greatly enhanced by using the cold plate. Transient state temperature variation indicates that the cold plate have quick thermal response in start-up process. It is beneficial to the heat dissipation of integrated module for high power density.
机译:提出了一种新型的冷却板,用于冷却具有高热通量和高散热要求的电子部件。引入了带有导板的S型冷板结构,以避免热量集中,并增加了传热面积。实验结果表明,新型冷板的最高切屑温度比常规冷板的最高切屑温度低约40%。进行了热性能优化,表明将热源安装在冷却板的两侧非常有效。与单侧热源相比,最高芯片温度仅增加20%。然而,在双面布置热源的有限空间中,散热量增加了一倍。此外,通过使用冷却板可以大大提高功率模块的集成密度。瞬态温度变化表明冷板在启动过程中具有快速的热响应。高功率密度有利于集成模块的散热。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号