Local heat transfer coefficients were measured on fin-tube heat exchanger with winglets using a single heater of 2 inch diameter and five different positions of winglet type vortex generators. The measurements were made at Reynolds number about 2250. Flow losses were determined by measuring the static pressure drop in the system. Results showed a substantial increase in the heat transfer with winglet type vortex generators. It has been observed that average Nusselt number increases by about 46% while the local heat transfer coefficient improves by several times as compared to plain fin-tube heat exchanger. The maximum improvement is observed in the re-circulation zone. The best location of the winglets was with Delta X = 0.5D and Delta Y= 0.5D. The increase in pressure drop for the existing situation was of the order of 18%. (c) 2004 Published by Elsevier Ltd.
机译:在带有小翼的翅片管式换热器上,使用直径为2英寸的单个加热器和小翼型涡流发生器的五个不同位置,测量局部传热系数。在约2250的雷诺数下进行测量。通过测量系统中的静压降来确定流量损失。结果表明,小翼型涡流发生器的传热显着增加。已经观察到,与普通翅片管热交换器相比,平均努塞尔数增加约46%,而局部传热系数提高数倍。在再循环区观察到最大的改进。小翼的最佳位置是Delta X = 0.5D和Delta Y = 0.5D。在现有情况下,压降的增加约为18%。 (c)2004年由Elsevier Ltd.发布。