首页> 外文期刊>Applied Microbiology and Biotechnology >Improvement on the modified Lowry method against interference of divalent cations in soluble protein measurement
【24h】

Improvement on the modified Lowry method against interference of divalent cations in soluble protein measurement

机译:改进的Lowry方法对可溶性蛋白质测量中二价阳离子干扰的改进

获取原文
获取原文并翻译 | 示例
           

摘要

This paper systematically investigated the interference of calcium and magnesium in protein measurement with a modified Lowry method first proposed by Fr?lund et al. (Appl Microbiol Biotechnol 43:755-761, 1995). This interference has in the past been largely ignored resulting in variable and unreliable results when applied to natural water matrices. We discovered significant formation of calcium and magnesium precipitates that lead to a decline in light absorbance at 750 nm during protein determination. Underestimation of protein concentration (sometimes even yielding negative concentrations) and low experiment reproducibility were demonstrated at high concentrations of divalent cations (e.g., [Ca~(2+)] over 1 mmolL~(-1)). To eliminate interference from calcium and magnesium, two pretreatment strategies were established based on cation exchange and dialysis. These pretreatments were convenient and were found to be highly effective in removing calcium and magnesium in protein samples. By using the modified Lowry method with these pretreatments, proteins in standard solutions and in wastewater samples were successfully quantified with good reliability and reproducibility. In addition, we demonstrated that simultaneous quantification of humic substances with the modified Lowry method was not affected by the two pretreatments. These approaches are expected to be applicable to protein and humic substance determination in different research fields, in cases where the modified Lowry method is sensitive to divalent cation concentrations.
机译:本文使用Fr?lund等人首先提出的改良Lowry方法,系统地研究了钙和镁对蛋白质测量的干扰。 (Appl Microbiol Biotechnol 43:755-761,1995)。过去,这种干扰在很大程度上被忽略,导致在应用于天然水基质时会产生可变且不可靠的结果。我们发现大量形成的钙和镁沉淀物会导致蛋白质测定过程中750 nm处的吸光度下降。在高浓度的二价阳离子(例如[Ca〜(2+)]超过1 mmolL〜(-1))时,蛋白质浓度低估(有时甚至产生负浓度)和低实验重现性。为了消除钙和镁的干扰,基于阳离子交换和透析建立了两种预处理策略。这些预处理很方便,并且在去除蛋白质样品中的钙和镁方面非常有效。通过将改良的Lowry方法与这些预处理结合使用,可以良好的可靠性和可重复性成功定量分析标准溶液和废水样品中的蛋白质。此外,我们证明了使用改良的Lowry方法同时定量腐殖质不受两种预处理的影响。在改良的Lowry方法对二价阳离子浓度敏感的情况下,这些方法有望适用于不同研究领域中的蛋白质和腐殖质测定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号