...
首页> 外文期刊>Angle Orthodontist >The effect of temperature on the mechanical behavior of nickel-Titanium orthodontic initial archwires
【24h】

The effect of temperature on the mechanical behavior of nickel-Titanium orthodontic initial archwires

机译:温度对镍钛正畸初始弓丝力学行为的影响

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Objectives: To investigate and compare the characteristics of commonly used types of traditional and heat-Activated initial archwires at different temperatures by plotting their load/deflection graphs and quantifying three parameters describing the discharge plateau phase. Materials and Methods: Forty-eight archwires of cross-sectional diameters ranging from 0.010 inches to 0.016 inches were obtained from seven different manufacturers. A modified three-point wire-bending test was performed on three analogous samples of each type of archwire at 55°C and 5°C, simulating an inserted archwire that is subjected to cold or hot drinks during a meal. For each resulting load/deflection curve the plateau section was isolated and the mean value of each parameter for each type of wire was obtained. Results: Permanent strain was exhibited by all wires tested at 55°C. Statistically significant differences were found between almost all wires for the three considered parameters when tested at 55°C and 5°C. Loads were greater at 55°C than at 5°C. Differences were also found between traditional and heat-Activated archwires, the latter of which generated longer plateaus at 55°C, shorter plateaus at 5°C, and lighter mean forces at both temperatures. The increase in average force seen with increasing diameter tended to be rather stable at both temperatures. Conclusions: All nickel-Titanium wires tested showed a significant change related to temperature in terms of behavior and force for both traditional and heat-Activated wires. Stress under high temperatures can induce permanent strain, whereas the residual strain detected at low temperatures can be recovered from as temperature increases.
机译:目的:通过绘制负载/挠度图并量化描述放电平稳阶段的三个参数,研究和比较不同温度下常用类型的传统和热激活初始弓丝的特性。材料和方法:从七家不同的制造商处获得四十八条弓丝,其横截面直径为0.010英寸至0.016英寸。在55°C和5°C下,对每种弓丝的三个类似样本进行了改进的三点弯曲测试,以模拟插入的弓丝在进餐期间受到冷或热饮料的影响。对于每个所得的载荷/挠度曲线,将平台部分隔离开,并获得每种导线类型的每个参数的平均值。结果:在55°C下测试的所有电线均表现出永久应变。在55°C和5°C下进行测试时,对于三个考虑的参数,几乎所有电线之间在统计上都存在显着差异。 55°C时的负载大于5°C时的负载。在传统的和热活化的弓丝之间也发现了差异,后者在55°C时产生更长的平稳期,在5°C时产生更短的平稳期,并且在两个温度下均产生较小的平均力。在两个温度下,随着直径的增加,平均力的增加趋于稳定。结论:测试的所有镍钛丝在行为和受力方面均显示出与传统和热激活丝有关的温度变化。高温下的应力会引起永久应变,而低温下检测到的残余应变可随温度升高而恢复。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号