Validation of a new method of detecting peripheral artery disease by determination of ankle-brachial index using an automatic blood pressure device.

机译:通过使用自动血压装置确定踝肱指数来检测外周动脉疾病的新方法的有效性。

获取原文
获取原文并翻译 | 示例
           

摘要

Peripheral artery disease (PAD) is a predictor of total and cardiovascular mortality; its most valuable simple index is the ankle-brachial index (ABI). The present study was designed to assess whether a commercially available automatic device could be used to determine ABI in comparison with the classical Doppler method. The ABI was defined as the ratio of systolic blood pressure at each ankle to the maximal brachial systolic pressure, a pathological index being defined for a ratio <0.90. The ABI were calculated in 219 consecutive patients (aged 55 +/-19 years) with systolic blood pressure measured either by using a mercury sphygmo-manometer and a continuous-wave Doppler probe or an automatic manometer Omron M4. This device has been validated for measurements in upper limbs, and so the authors undertook validation in the lower limbs versus intraarterial measurements. There was an excellent correlation between intraarterial measurements and automatic readings in the range of 70-220 mm Hg, r=0.99, p<0.001. The systolic pressures measured in upper limbs correlated well in the right (r=0.87, p<0.001) and the left (r=0.89, p<0.001) upper limbs; and in the left (r=0.72, p<0.001) and the right (r=0.68, p<0.001) lower limbs. Correlations between ABI in both methods were good in the left (r=0.66, p<0.001) and the right (r=0.61, p<0.001) lower limbs. The sensitivity (76%), specificity (95%), positive predictive value (86%), negative predictive value (90%), and global accuracy (89%) of a pathological automatic index to predict an abnormal Doppler index were good. The use of a simple, automatic blood pressure device to determine ABI appears feasible, easy, and precise. It would provide a practical tool for physicians not trained in Doppler to detect PAD.
机译:周围动脉疾病(PAD)是总死亡率和心血管疾病死亡率的预测指标;它最有价值的简单指标是踝肱指数(ABI)。本研究旨在评估与经典多普勒方法相比,是否可以使用商用自动设备确定ABI。 ABI定义为每个脚踝的收缩压与最大肱动脉收缩压的比率,病理指数定义为<0.90。通过使用水银血压计和连续波多普勒探头或自动血压计Omron M4对219位连续收缩压(55 +/- 19岁)的收缩压患者进行计算。该设备已经过上肢测量的验证,因此作者对下肢和动脉内测量进行了验证。在70-220 mm Hg的范围内,动脉内测量与自动读数之间存在极好的相关性,r = 0.99,p <0.001。右上肢(r = 0.87,p <0.001)和左上肢(r = 0.89,p <0.001)的上肢收缩压相关性很好。左(r = 0.72,p <0.001)和右(r = 0.68,p <0.001)下肢。两种方法中,左下肢(r = 0.66,p <0.001)和右下肢(r = 0.61,p <0.001)的ABI相关性都很好。病理自动指标预测多普勒指数异常的敏感性(76%),特异性(95%),阳性预测值(86%),阴性预测值(90%)和总体准确性(89%)都很好。使用简单的自动血压设备确定ABI似乎可行,容易且精确。这将为未经多普勒训练的医生提供实用的工具来检测PAD。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号