SUMMARY: BACKGROUND The Finometer (FMS, Finapres Measurement Systems, Arnhem, Netherlands), which is the improved successor of the Finapres (TNO Biomedical Instrumentation, Amsterdam, Netherlands), measures finger arterial blood pressure non-invasively and computes other cardiovascular parameters from the computed aortic-flow waveform. The usability of the Finometer would depend on whether it is sensitive enough to detect small cardiovascular changes. The aim was therefore to determine the sensitivity of the Finometer regarding acute and longer-term cardiovascular changes.DESIGN AND METHODS The sensitivity of the Finometer regarding the acute effect of 200 mg caffeine was determined with a double-blind, placebo-controlled crossover study which included 38 young male subjects. Finometer recordings were performed during four occasions at fasting level and after 30 min of ingestion. To evaluate the sensitivity of the Finometer in recording longer-term effects of a daily dosage of 1000 mg vitamin C, 800 mgvitamin E and 10 mg folic acid, 14 young males took placebo and 17 took the vitamins for 12 weeks in a double-blind study. Two recordings were performed at baseline and two after 12 weeks.RESULTS After caffeine ingestion significantly (P<0.05) higher systolic, diastolic and mean blood pressure values than resting values were obtained. The arterial compliance was significantly lower after caffeine ingestion, whereas heart rate, peripheral resistance, stroke volume and cardiac output did not change significantly. No differences were shown after intake of placebo. Concerning the effects of vitamin intake, the vitamin group indicated a significant decrease in systolic blood pressure (P=0.03) whereas the placebo group indicated no significant differences after 12 weeks.CONCLUSIONS The results suggest that the improved Finometer might be a sensitive instrument in the recording of relative small acute and longer-term changes in cardiovascular function, but more studies are necessary before final conclusions can be drawn.
机译:摘要:背景Finometer(FMS,Finapres测量系统,荷兰阿纳姆)是Finapres(TNO生物医学仪器,荷兰阿姆斯特丹)的改进后继产品,它无创地测量手指动脉血压,并从中计算出其他心血管参数计算的主动脉流波形。 Finometer的可用性取决于它是否足够灵敏以检测小的心血管变化。因此,目的是确定Finometer对急性和长期心血管变化的敏感性。设计和方法通过双盲,安慰剂对照的交叉研究确定Finometer对200 mg咖啡因急性影响的敏感性。包括38名年轻男性受试者。在四次禁食时和摄入30分钟后进行Finometer记录。为了评估Finometer在记录每日剂量1000毫克维生素C,800毫克维生素E和10毫克叶酸的长期影响中的敏感性,在双盲试验中,有14位男性服用了安慰剂,而17位男性服用了12周的维生素研究。结果在基线时进行了两次记录,在12周后进行了两次记录。结果摄入咖啡因后,收缩压,舒张压和平均血压值均显着高于静息值(P <0.05)。摄入咖啡因后,动脉顺应性明显降低,而心率,外周阻力,中风量​​和心输出量没有明显变化。服用安慰剂后无差异。关于维生素摄入的影响,维生素组显示收缩压显着降低(P = 0.03),而安慰剂组显示在12周后无显着差异。结论结果表明,改进的Finometer可能是敏感的仪器。记录相对较小的急性和长期心血管功能变化,但尚需更多研究才能得出最终结论。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号