首页> 外文期刊>Analytical chemistry >Development of an Automatic Column Chromatography Separation Device for Metal Isotope Analysis Based on Droplet Counting
【24h】

Development of an Automatic Column Chromatography Separation Device for Metal Isotope Analysis Based on Droplet Counting

机译:基于液滴计数的金属同位素分析自动柱色谱分离装置的研制

获取原文
获取原文并翻译 | 示例
           

摘要

A novel, simple, cost-effective, reliable, and practical automatic column chromatography separation device capable of simultaneously purifying samples for radiogenic and non-traditional stable isotope analysis has been developed. The device avoids the use of any pump and features eluent driving by the siphon effect (gravity) and quantitative control by infrared droplet counting. Several factors affecting the control of droplets were investigated, including types and concentrations of eluents and the height of the liquid level. Results showed that accurate dripping of the eluent could be readily achieved by controlling the number of droplets under selected conditions. The separation performance of the device was first demonstrated by the elution of Sr and Cd in synthetic matrix solutions. The recoveries of Sr and Cd samples were better than 87.6 and 95.0%, respectively, and the whole procedure blank was about 0.3 ng for Sr and 0.1 ng for Cd. Finally, the reliability of the device was further validated by the purification of Sr and Cd from different geological reference materials (NIST 2711a, Nod-A-1, BCR-2, and BHVO-2). The determined Cd and Sr isotope values agree well with their reference values within the uncertainty range. All these results clearly demonstrate the reliability and practicability of the proposed device, which provides a promising method for the automated purification of isotope samples.
机译:开发了一种新型、简单、经济、可靠、实用的自动柱色谱分离装置,能够同时净化放射性同位素和非传统稳定同位素分析样品。该设备避免使用任何泵,通过虹吸效应(重力)驱动洗脱液,并通过红外液滴计数进行定量控制。研究了影响液滴控制的几个因素,包括洗脱液的类型和浓度以及液位的高度。结果表明,在选定的条件下,通过控制液滴数,可以很容易地实现洗脱液的精确滴注。该装置的分离性能首先通过合成基质溶液中Sr和Cd的洗脱来证明。Sr和Cd样品的回收率分别优于87.6%和95.0%,整个程序空白为Sr约0.3ng,Cd约0.1ng。最后,通过从不同地质标准物质(NIST 2711a、Nod-A-1、BCR-2和BHVO-2)中提纯锶和镉,进一步验证了该装置的可靠性。测定的Cd和Sr同位素值在不确定度范围内与其参考值吻合良好。所有这些结果清楚地证明了该装置的可靠性和实用性,为同位素样品的自动纯化提供了一种有前途的方法。

著录项

  • 来源
    《Analytical chemistry》 |2021年第19期|共8页
  • 作者单位

    China Univ Geosci Wuhan State Key Lab Biogeol &

    Environm Geol Wuhan 430074 Peoples R China;

    China Univ Geosci Wuhan State Key Lab Biogeol &

    Environm Geol Wuhan 430074 Peoples R China;

    China Univ Geosci Wuhan State Key Lab Biogeol &

    Environm Geol Wuhan 430074 Peoples R China;

    China Univ Geosci Wuhan State Key Lab Biogeol &

    Environm Geol Wuhan 430074 Peoples R China;

    China Univ Geosci Wuhan State Key Lab Biogeol &

    Environm Geol Wuhan 430074 Peoples R China;

    China Univ Geosci Wuhan Fac Mat Sci &

    Chem Wuhan 430074 Peoples R China;

    China Univ Geosci Wuhan Sch Mech Elect &

    Elect Informat Wuhan 430074 Peoples R China;

    China Univ Geosci Wuhan State Key Lab Biogeol &

    Environm Geol Wuhan 430074 Peoples R China;

    China Univ Geosci Wuhan State Key Lab Biogeol &

    Environm Geol Wuhan 430074 Peoples R China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 分析化学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号