Flexible ureteroscopy is the keystone of modern kidney stone treatment. Although a simple surgical technique achieves good clinical results and a low complication rate, there are high demands on the surgeon's dexterity and ergonomic restrictions. Robotic-assisted flexible ureteroscopy (rfURS) could overcome these limitations. After 4 years of use of rfURS at a tertiary stone center, performance factors were analyzed to define the role of rfURS in kidney stone management. A rfURS system was installed in August 2014 at the SLK Kliniken (Heilbronn, Germany). Treatment data of N=240 consecutive patients undergoing rfURS were prospectively collected and analyzed. The patient cohort represents typical stone formers. N=240 renal units containing 443 stones with an average stone load of 1798 mm~3 were treated. Surgical parameters as well as the peri- and postoperative complications were recorded, analyzed and compared to the current data in the literature. OR time 91 min, stone treatment time 55 min, stone treatment efficacy 33 mm~3/min; perioperative complications 5.4%; robot times: preparation 5 min, docking 5 min, console time to stone contact 6 min, console time 75 min; postoperative complications 6.7%; postoperative length of stay 1.5 days; stone-free rate (residuals <2 mm) 90% and re-treatment rate 8.75%. This consecutive series represents real-life data about the utilization of rfURS. The detailed analysis of performance factors revealed the successful utilization of the first generation of robotic systems in endourologic stone surgery, and indicates that the robot performs comparably to conventional flexible URS. Optimal ergonomics maintain the surgeon's endurance in long-lasting surgeries.
机译:输尿管软镜检查是现代肾结石治疗的基础。虽然简单的手术技术可以获得良好的临床效果和较低的并发症发生率,但对外科医生的灵活性和人体工程学的限制有很高的要求。机器人辅助柔性输尿管镜(rfURS)可以克服这些限制。在三级结石中心使用rfURS 4年后,对性能因素进行分析,以确定rfURS在肾结石管理中的作用。2014年8月,SLK Kliniken(德国海尔布罗恩)安装了rfURS系统。前瞻性收集并分析了240例连续接受rfURS治疗的患者的治疗数据。患者队列代表典型的结石形成者。N=240个肾单位,含443个结石,平均结石负荷1798mm~3。记录、分析手术参数以及围手术期和术后并发症,并与文献中的当前数据进行比较。或时间91min,结石治疗时间55min,结石治疗效果33mm~3/min;围手术期并发症5.4%;机器人时间:准备5分钟,对接5分钟,控制台与石头接触6分钟,控制台时间75分钟;术后并发症6.7%;术后住院时间1.5天;结石清除率(残留<2mm)90%,再处理率8.75%。这个连续的系列代表了关于RFUR利用率的真实数据。对性能因素的详细分析揭示了第一代机器人系统在泌尿外科手术中的成功应用,并表明该机器人的性能与传统的柔性URS相当。最佳的人体工学设计可在长期手术中保持外科医生的耐力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号