Failure of pump shaft (P116-1) of high-pressure water pump occurred during coke removal. Shaft material (3Cr13) demonstrated yield and tensile strength of 737 and 910 MPa, respectively. Failure analysis was performed to determine the cause of failure, which was a fracture at the pump shaft located at the journal. Macroscopic, metallographic, chemical composition, hardness, SEM, and EDS analyses were used in the failure analysis. Metallographic and SEM analyses revealed that fatigue cracks are related to corrosion and geometrical shape. Fatigue crack initiation at the disconnected area of the chromium plating layer weakened fatigue resistance. Causes of incomplete chromium plating at the shaft journal and keyway should be investigated further.
机译:高压水泵泵轴(P116-1)在除焦过程中发生故障。轴材料(3Cr13)的屈服强度和抗拉强度分别为737和910 MPa。进行故障分析以确定故障原因,即轴颈处的泵轴断裂。失效分析采用了宏观、金相、化学成分、硬度、SEM和EDS分析。金相和扫描电镜分析表明,疲劳裂纹与腐蚀和几何形状有关。镀铬层断开区域的疲劳裂纹萌生削弱了疲劳抗力。应进一步调查轴颈和键槽镀铬不完全的原因。