Equal sensitivity of early and late scans after injection of FDG for the detection of Alzheimer pattern: An analysis of 3D PET data from J-ADNI, a multi-center study

机译:注射FDG后早期和晚期扫描对检测阿尔茨海默氏病的敏感性相同:来自J-ADNI的3D PET数据分析,一项多中心研究

获取原文
获取原文并翻译 | 示例
       

摘要

Objective: To determine the optimal accumulation time for three-dimensional positron emission tomography (3D-PET) with 18F-2-fluoro-2-deoxy-d- glucose (18F-FDG) to detect the brain uptake pattern typical of Alzheimer's disease (AD). Methods: Patients with mild AD or amnestic mild cognitive impairment (MCI) and normal control subjects were recruited in the Japanese Alzheimer's disease neuroimaging initiative and examined with a PET scan during the 30-60 min after FDG injection. Three independent blinded experts interpreted the 30- to 60-min sum images, and images of patients with AD and MCI presenting AD patterns and normal subjects presenting normal patterns were used in the analysis. Early-scan (ES) and late-scan (LS) images were obtained from the data acquired at 30-35 min and 55-60 min after the injection, respectively. Separate target regions of interest (ROI) for ES and LS were defined as areas of significant reductions in the posterior cingulate and parietotemporal lobe in both hemispheres from the results of an initial cohort with 21 patients (AD 16, MCI 5) and 19 controls. A subsequent sample of 36 (AD 9, MCI 27) patients and 38 controls were used to compare the diagnostic capability of ES and LS using Z scores within the target ROI in individual statistical parametric mapping analysis. Results: Compared to LS, ES showed lower activity in the frontal lobes and higher activity in the venous sinus than LS; however, the diagnostic capability of ES and LS did not significantly differ (sensitivity 0.97 and 0.97, specificity 0.82 and 0.84, area under the receiver-operating characteristic curve 0.96 and 0.97, respectively). Conclusions: For a qualitative diagnosis of the AD pattern in 3D FDG-PET, results of ES were equivalent to those of LS. ES may be an option to shorten the entire PET procedure time, particularly in diagnosing early stages of AD.
机译:目的:确定使用18F-2-氟-2-脱氧-d-葡萄糖(18F-FDG)进行三维正电子发射断层扫描(3D-PET)的最佳累积时间,以检测典型的阿尔茨海默氏病脑吸收模式(广告)。方法:在日本阿尔茨海默氏病神经影像学倡议中招募患有轻度AD或轻度轻度认知障碍(MCI)的患者和正常对照组,并在注射FDG后30-60分钟内进行PET扫描。三名独立的盲人专家对30到60分钟的总图像进行了解释,并在分析中使用了呈现AD模式的AD和MCI患者和呈现正常模式的正常受试者的图像。早期扫描(ES)和后期扫描(LS)图像分别从注射后30-35分钟和55-60分钟获得的数据获得。 ES和LS的独立目标区域(ROI)被定义为与最初队列的21名患者(AD 16,MCI 5)和19名对照的结果相比,两个半球后扣带和顶颞叶显着减少的区域。随后的36位(AD 9,MCI 27)患者和38位对照样本被用于比较ES和LS在个别统计参数映射分析中使用目标ROI内的Z评分的诊断能力。结果:与LS相比,ES的额叶活动性较低,静脉窦的活动性较高。但是,ES和LS的诊断能力没有显着差异(灵敏度分别为0.97和0.97,特异性0.82和0.84,受体工作特征曲线下的面积0.96和0.97)。结论:为了对3D FDG-PET中AD模式进行定性诊断,ES的结果与LS的结果相同。 ES可能是缩短整个PET手术时间的一种选择,特别是在诊断AD的早期阶段。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号