首页> 外文期刊>Analytica chimica acta >A novel approach for the determination of the toal concentration of acids in aqueous solutions by simultaneous diffusion limited current for reduction of acids and pH measurements
【24h】

A novel approach for the determination of the toal concentration of acids in aqueous solutions by simultaneous diffusion limited current for reduction of acids and pH measurements

机译:通过同时扩散限制电流减少酸和pH值来测定水溶液中酸总浓度的新方法

获取原文
获取原文并翻译 | 示例
           

摘要

A novel method is presented for the detection of acid content in aqueous solutions. The method is based on simultaneous measurements, in the test solution, of the overall steady-state limiting current arising from the reduction of the acids, and pH, along with the use of a theoretical expression. The current is recorded with platinum mieroelectrodes. while pH is measured ~Ii ~ ‘~las.s etectrodes To retate current and pH data, an “amperometric calibration” of the glass electrodes is performed.X~rat&o~x eog.susiows axe ohtained from, a senes of combined current/PH measurements in so1uxson~ containing a range or concentrations of the strong acid HClO4. This procedure overcomes the problems associated with the unknown activity coefficient of H± and liquid junction potential contributions involved in the pH measurements. The new methodology is tested in several aqueous solutions containing mono- and polyprotic acids either alone or in mixture; buffered solutions are also considered. It is shown that, under the latter conditions, special cases exist. in which the total acid concentration is achieved by overall steady-state limiting current measurements alone. The accuracy of the proposed method is tested against classical titration procedures. The discrepancies between the two methods do not exceed approx 5%.
机译:提出了一种检测水溶液中酸含量的新方法。该方法基于在测试溶液中同时测量由于酸和pH降低而产生的总体稳态极限电流,以及使用理论表达式。用铂微电极记录电流。在测量pH值的同时,为了反射电流和pH数据,对玻璃电极进行了“电流安培校准”。在溶液中的PH测量值包含一定范围或浓度的强酸HClO4。该程序克服了与未知的H±活度系数和pH测量中涉及的液体连接电位有关的问题。新方法在含有单质子酸和多质子酸的几种水溶液中进行了测试,这些水溶液既可以单独使用也可以混合使用。还考虑了缓冲溶液。结果表明,在后一种情况下,存在特殊情况。其中仅通过整体稳态极限电流测量即可获得总酸浓度。相对于传统的滴定程序测试了所提出方法的准确性。两种方法之间的差异不超过5%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号