...
首页> 外文期刊>Analytica chimica acta >Rapid on-line preconcentration and suppressed micro-bore ion chromatography of part per trillion levels of perchlorate in rainwater samples
【24h】

Rapid on-line preconcentration and suppressed micro-bore ion chromatography of part per trillion levels of perchlorate in rainwater samples

机译:快速在线预浓缩和抑制的微孔离子色谱法,用于测量雨水样品中的万亿分之几的高氯酸盐

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The development of a rapid method for the determination of perchlorate in rain and drinking waters is presented. In the optimised method, an on-line preconcentration technique was employed utilising a 10 mm x 4.6 mm Phenomenex Onyx monolithic guard cartridge coated with (N-dodecyl-N,N-dimethylammonio)undecanoate for selective preconcentration, with subsequent elution into a fixed volume injection loop ('heart-cut' of the concentrator column eluate) and separation using an IonPac AS 16 (250 mm x 2 mm) anion exchange column and a potassium hydroxide concentration gradient. Off-line optimisation studies showed that the coated monolith displayed near quantitative recovery up to 50 mu g/L perchlorate level from standards prepared in reagent water. On-line preconcentration of perchlorate obtained detection limits down to 56 ng/L in reagent water, between 70 and 80 ng/L in rainwater samples and 2.5 mu g/L in non-pretreated drinking water. After an additional sample sulphate/carbonate removal step, low ng/L perchlorate concentrations could also be observed in drinking water. The complete on-line method exhibited reproducibility for n = 10 replicate runs of R.S.D. <= 3% for peak height/area and R.S.D. = 0.08% for retention time. The optimised method, of 20 min total duration, was applied to the determination of perchlorate by standard addition in 10 rainwater samples and one drinking water sample. Concentrations of perchlorate present ranged from below the detection limit for four rainwater samples, with another three samples showing perchlorate present at between 70 and 100 ng/L, and one sample showing perchlorate present at 2.8 mu g/L. Levels of 1.1 mu g/L in the drinking water sample were also recorded. (c) 2006 Elsevier B.V. All rights reserved.
机译:介绍了一种测定雨水和饮用水中高氯酸盐的快速方法的开发。在优化的方法中,采用在线预浓缩技术,该技术采用10毫米x 4.6毫米Phenomenex Onyx整体式保护柱,其中包有(N-十二烷基-N,N-二甲基铵)十一烷酸酯,用于选择性预浓缩,随后洗脱至固定体积注射回路(浓缩柱洗脱液的“心脏切割”),并使用IonPac AS 16(250 mm x 2 mm)阴离子交换柱和氢氧化钾浓度梯度进行分离。离线优化研究表明,从试剂水中制备的标准物中,涂覆的整体显示出接近定量的回收率,高氯酸盐含量高达50μg / L。在线高浓度的高氯酸盐检测试剂中的检测限低至56 ng / L,雨水样品中的检测限为70至80 ng / L,未经预处理的饮用水中的检测限为2.5μg / L。经过额外的样品硫酸盐/碳酸盐去除步骤后,在饮用水中还可以观察到低ng / L高氯酸盐浓度。完整的在线方法对R.S.D.的n = 10次重复运行显示出可重复性。 <=峰高/面积和R.S.D.的3% = 0.08%的保留时间。将优化的方法(总持续时间为20分钟)用于通过在10个雨水样品和1个饮用水样品中标准添加来测定高氯酸盐。存在的高氯酸盐浓度范围低于四个雨水样品的检出限,另外三个样品显示高氯酸盐含量在70至100 ng / L之间,一个样品显示高氯酸盐含量为2.8μg / L。还记录了饮用水样品中1.1μg/ L的水平。 (c)2006 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号