...
首页> 外文期刊>Acta Obstetricia et Gynecologica Scandinavica: Official Publication of the Nordisk Forening for Obstetrik och Gynekologi >Longer distance between umbilical cord insertions is associated with spontaneous twin anemia polycythemia sequence
【24h】

Longer distance between umbilical cord insertions is associated with spontaneous twin anemia polycythemia sequence

机译:脐带插入之间的较长距离与自发双胞咽性多胆血症序列相关

获取原文
获取原文并翻译 | 示例

摘要

Introduction The aim of the study was to investigate the placental characteristics in spontaneous twin anemia polycythemia sequence. Material and methods A retrospective case-control study of spontaneous twin anemia polycythemia sequence, twin-to-twin transfusion syndrome and normal monochorionic diamniotic twin pregnancies was performed. The primary outcome was placental characteristics. Results The prevalence of artery-artery anastomoses in spontaneous twin anemia polycythemia sequence and twin-to-twin transfusion syndrome groups was significantly lower than in the normal monochorionic diamniotic twin group (40.0% vs 33.3% vs 88.8%, respectively,P < .001). The total number of vascular anastomoses in the spontaneous twin anemia polycythemia sequence group (with range given in parentheses) was significantly lower than in the two control groups (3 [1-6] vs 5 [1-14] vs 6 [1-20],P = .001/<.001/.794). The number of artery-vein anastomoses in the spontaneous twin anemia polycythemia sequence was significantly lower than in the two control groups (2 [1-5] vs 4 [1-13] vs 5 [1-19],P = .011/.001/1.000). The total diameter of all vascular anastomoses was significantly smaller in the spontaneous twin anemia polycythemia sequence than in the two control groups (0.9 mm [0.3-4.7] vs 5.2 mm [0.8-24.6] vs 7.3 mm [1.0-25.1],P < .001/<.001/.104), as was the total diameter of artery-to-artery anastomoses (0.5 mm [0.3-1.3] vs 2.0 mm [0.5-11.8] vs 2.3 mm [0.7-9.7],P = .003/<.001/1.000) and the total diameter of artery-to-vein anastomoses (0.8 mm [0.3-2.1] vs 4.6 mm [0.8-15.3] vs 4.0 mm [0.2-21.8],P < .001/<.001/1.000). The ratio between the distance of the two umbilical cords insertion points and the placental maximum diameter in the spontaneous twin anemia polycythemia sequence group was significantly larger than in the two control groups (0.78 [0.49-0.99] vs 0.64 [0.32-1.00] vs 0.55 [0.05-1.00],P = .033/<.001/.138). Conclusions In spontaneous twin anemia polycythemia sequence placentas, the number of superficial vascular anastomoses is lower, their diameter is smaller and the distance between the two umbilical cord insertion points is longer.
机译:None

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号