首页> 外文期刊>Analytical chemistry >Old reliable benchtop GC/MS
【24h】

Old reliable benchtop GC/MS

机译:旧的可靠台式GC / MS

获取原文
获取原文并翻译 | 示例
       

摘要

The market for GC/MS remains strong for food and environmental applications. The old saying, "If it ain't broke, don't fix it," could be applied to benchtop GC/MS systems. While experts agree that the general performance and functional capabilities have increased since Analytical Cbemistry last reviewed the instruments (1999, 71, 401 A-406 A), they say the changes have not been revolutionary. "There have been improvements over the last five years, but I would say the improvements have generally been incremental. In the benchtop GC/MS area, there hasn't been a shining new instrument that has been developed," says Nicholas Snow of Seton Hall University. "I think that's an indication of the fact that the technology has been well developed," says James Yano of Agilent Technologies. Experts also think GC/MS hasn't seen any major changes recently because instrument companies have focused their attention on techniques such as LC/MS for biomedical and pharmaccutical applications. Nonetheless, the market for GC/MS systems remains stable. Tables 1-4 list selected commcrcially available quadrupole, ion trap, TOF, and magnetic sector benchtop GC/MS instruments. The tables are not meant to be comprehensive; some vendors also offer products not listed here. Experts agree that two changes have occurred in GC/MS instrumentation over the past five years. For one, the general cost per analysis has decreased. Matthew Booth of the University of Florida states, "I think you can get a lot more for your dollars now than [five years ago]. GC/MS instruments with differential pumping and chemical ionization sources used to be an option only for research laboratories. These options are now available for benchtop systems for under
机译:对于食品和环境应用而言,GC / MS市场仍然强劲。俗话说:“如果没有破裂,就不要修理它”,可以应用于台式GC / MS系统。尽管专家们一致认为,自从分析Cbemistry上次审查这些工具(1999,71,401 A-406 A)以来,总体性能和功能有所提高,但他们说,这些变化并不是革命性的。 Seton的Nicholas Snow说:“过去五年来已有改进,但我想说这些改进通常是渐进的。在台式GC / MS领域,还没有开发出新的闪亮仪器。”霍尔大学。安捷伦科技公司的詹姆斯·亚诺说:“我认为这表明该技术已经得到了很好的发展。”专家们还认为,GC / MS近期未见任何重大变化,因为仪器公司将注意力集中在诸如LC / MS等生物医学和药物应用技术上。尽管如此,GC / MS系统的市场仍保持稳定。表1-4列出了市售的四极杆,离子阱,TOF和磁性扇形台式GC / MS仪器。这些表并不全面。一些供应商还提供此处未列出的产品。专家们认为,过去五年来,GC / MS仪器发生了两次变化。首先,每次分析的总成本已降低。佛罗里达大学的马修·布斯(Matthew Booth)表示:“我认为,与5年前相比,现在您可以获得更多的美元。具有差分泵和化学电离源的GC / MS仪器过去只是研究实验室的一种选择。这些选项现在可用于台式系统

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号