首页> 外文期刊>Applied thermal engineering: Design, processes, equipment, economics >Experimental study of temperature characteristic and energy consumption of a large-scale cold storage with buried pipe cooling
【24h】

Experimental study of temperature characteristic and energy consumption of a large-scale cold storage with buried pipe cooling

机译:埋藏管道冷却大规模冷库温度特性和能耗的实验研究

获取原文
获取原文并翻译 | 示例
           

摘要

In this paper, a buried pipe cooling system is proposed for use in cold storage. To evaluate this cold storage system, the temperature non-uniformity and fluctuation are evaluated, and energy consumption is measured. The results show that the temperature in this cold storage unit is stable; the temperature non-uniformity ranges from 0.56 to 0.71 degrees C, and the temperature fluctuation ranges from 0.25 to 0.72 degrees C. The temperature characteristics at various vertical heights are substantially different. In the upper and middle layers, the temperature is relatively low. In the middle layer, the temperature characteristic is most stable (the temperature non-uniformity ranges from 0.21 to 0.33 degrees C, and the fluctuation is from 0.16 to 0.48 degrees C) relative to the lower and upper layers. Moreover, the specific energy consumption (SEC) of this cold storage unit is only 7.04 kW.h.m(-3).year(-1), which is lower than that of many previously studied cold storage units, due to numerous factors. Based on the results, certain heights are recommended to better maintain the quality of the food in storage. To conserve energy consumption in the later period of the cold storage operation, one option is to increase the cost in the early stage and apply various energy-saving methods during design and construction.
机译:在本文中,提出了一种用于冷库的掩埋管冷却系统。为了评估该冷库系统,评估温度不均匀性和波动,并测量能量消耗。结果表明,该冷藏单元中的温度稳定;温度不均匀性范围为0.56至0.71℃,温度波动范围为0.25至0.72℃。各种垂直高度的温度特性基本不同。在上层和中层,温度相对较低。在中间层中,温度特性是最稳定的(温度不均匀性范围为0.21至0.33℃,并且波动相对于下层和上层为0.16至0.48℃。此外,该冷库单元的特定能量消耗(秒)仅为7.04 kW.h.m(-3).Year(-1),其低于许多先前研究的冷库单元,由于许多因素。根据结果​​,建议某些高度更好地保持储存中食物的质量。为了节省在冷藏操作的后期能源消耗中,一种选择是提高早期阶段的成本,并在设计和施工期间应用各种节能方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号