首页> 外文期刊>Applied thermal engineering: Design, processes, equipment, economics >Experimental study of an R290 split-type air conditioner using a falling film condenser
【24h】

Experimental study of an R290 split-type air conditioner using a falling film condenser

机译:使用落膜冷凝器的R290分流式空调的实验研究

获取原文
获取原文并翻译 | 示例
       

摘要

R290 is one of the most promising refrigerants for split-type air conditioners (STAC) because of its excellent environmental and thermodynamic properties. However, R290 has flammability. There is necessary to improve the STAC design to reduce the refrigerant charge for the safety use. This work proposes a novel falling film condensing technology to address this problem. The novel condenser was setup on a STAC and tested in the standard psychrometric chamber. Experimental results show that using falling film condenser significantly reduces the refrigerant charge. The best performance is obtained with 290 g of R290 charge, for which the cooling capacity is 2690 W and the coefficient of performance (COP) is 3.55, meeting the safety and energy efficiency requirements. This result provides a new technical route for the application of an R290 STAC.
机译:R290是由于其优异的环境和热力学性能,是分裂式空调(StAC)最有前途的制冷剂之一。 但是,R290具有易燃性。 有必要改善STAC设计,以减少安全使用的制冷剂。 这项工作提出了一种新颖的薄膜凝结技术来解决这个问题。 新型冷凝器在STAC上设置并在标准的心理测量室中进行测试。 实验结果表明,使用下降膜冷凝器显着降低了制冷剂的电荷。 使用290g R290电荷获得最佳性能,其中冷却能力为2690W,性能系数(COP)为3.55,满足安全性和能效要求。 该结果为应用R290 Stac提供了一种新的技术路线。