...
首页> 外文期刊>Analytica chimica acta >Smartphone-based fluorescent lateral flow immunoassay platform for highly sensitive point-of-care detection of Zika virus nonstructural protein 1
【24h】

Smartphone-based fluorescent lateral flow immunoassay platform for highly sensitive point-of-care detection of Zika virus nonstructural protein 1

机译:基于智能手机的荧光横向流动免疫测定平台,用于Zika病毒非结构蛋白的高度敏感性的护理点检测

获取原文
获取原文并翻译 | 示例
           

摘要

Simple, inexpensive, and rapid diagnostic tests in low-resource settings with limited laboratory equipment and technical expertise are instrumental in reducing morbidity and mortality from epidemic infectious diseases. We developed a smartphone-based fluorescent lateral flow immunoassay (LFIA) platform for the highly sensitive point-of-care detection of Zika virus nonstructural protein 1 (ZIKV NS1). An attachment was designed and 3D-printed to integrate the smartphone with external optical and electrical components, enabling the miniaturization of the instrument and reduction in cost and complexity. Quantum dot microspheres were utilized as probes in fluorescent LFIA because of their extremely bright fluorescence signal. This approach can achieve quantitative point-of-care detection of ZIKV NS1 within 20 min. Limits of detection (LODs) in buffer and serum were 0.045 and 0.15 ng mL(-1), respectively. Despite the high structural similarity, a high-level Dengue virus NS1 as interferent showed limited cross-reactivity. Furthermore, this assay was successfully applied to detecte ZIKV NS1 and virions spiked in complex biological samples, indicating its practical application capability. Given its low cost, compact size, and excellent analytical performance, the proposed smartphone-based fluorescent LFIA platform holds considerable potential in rapid and accurate point-of-care detection of ZIKV NS1 and provides new insight into the design and application of molecular diagnostic methods in low-resource settings. (C) 2018 Published by Elsevier B.V.
机译:利用有限的实验室设备和技术专业知识的低资源设置简单,廉价和快速的诊断测试是降低流行病传染病的发病率和死亡率的乐器。我们开发了一种基于智能手机的荧光横向流动免疫测定(LFIA)平台,用于Zika病毒非结构蛋白1(ZIKV NS1)的高度敏感点检测。设计了一个附件和3D打印的,以将智能手机与外部光学和电气部件集成,从而实现仪器的小型化并降低成本和复杂性。由于其极明亮的荧光信号,量子点微球用作荧光LFIa的探针。这种方法可以在20分钟内实现ZIKV NS1的定量护理点检测。缓冲液和血清中的检测限值分别为0.045和0.15ng mL(-1)。尽管结构相似高,但是作为干扰的高级登革病毒NS1显示出有限的交叉反应性。此外,该测定成功地应用于检测Zikv NS1和在复杂的生物样品中掺入的病毒粒子,表明其实际应用能力。鉴于其低成本,紧凑尺寸和优异的分析性能,所提出的智能手机的荧光灯利益LFIA平台在ZIKV NS1的快速和准确的护理点检测方面具有相当大的潜力,并提供了新的洞察分子诊断方法的设计和应用在低资源设置中。 (c)2018由elsevier b.v发布。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号