Metabolome analysis using capillary electrophoresis (CE) coupled with high-resolution mass spectrometry (HRMS) has the potential to improve coverage of metabolite detection because of its high selectivity and sensitivity. Configuration of the interface between CE and HRMS to meet the ground connection is essential for enabling independent regulation of the electrical currents in the CE and electrospray field. In the present study, we applied an electrospray-ionization adapter equipped with a grounded nebulizer to CE-HRMS and tested the analytical performance for 34 charged compounds. The extracted-ion electropherograms, consisting of seven sets of isomers, showed reasonable peak shapes and separation for the annotation of each metabolite. The levels of 34 target analytes in a standard mixture were determined with a dynamic range of at least 10(2), maintaining linearity with r(2) 0.9. The repeatability and intermediate precision above the lower limit of quantification showed the relative standard deviation to be lower than 20%. In the spike-recovery experiment, 27 of the 34 metabolites in plasma extract were recovered at a rate of 80 to 120%, suggesting high accuracy. Furthermore, we assessed the feasibility of our platform in metabolome analysis using human-plasma extract. The results showed successful detection of 270 metabolites, indicating the potential of our platform to yield higher coverage of the metabolome. In addition, analysis of dilution integrity demonstrated the quantitative ability of metabolome analysis with CE-HRMS, although the existence of saturation or matrix effects were seen in the case of 33 of the metabolites. This study indicates that our platform has great potential for large-scale metabolome analysis of plasma for biological studies and clinical biomarker screening.
机译:使用毛细管电泳(CE)与高分辨率质谱(HRMS)耦合的代谢物分析具有可提高代谢物检测的覆盖,因为其选择性高,选择性高,灵敏度。 CE和HRMS之间的接口配置以满足地面连接对于实现CE和电喷雾场中的电流的独立调节至关重要。在本研究中,我们将配备有接地的雾化器的电喷雾电离适配器施加到Ce-HRMS上并测试了34个带电化合物的分析性能。由七套异构体组成的提取离子电泳图显示出合理的峰形状和分离用于每个代谢物的注释。测定标准混合物中34种靶分析物的水平,其动态范围为至少10(2),保持与R(2)&GT的线性度; 0.9。高于定量下限的可重复性和中间精度显示相对标准偏差低于20%。在穗恢复实验中,在血浆提取物中的34个代谢物中的27个以80%〜120%的速率回收,表明高精度。此外,我们评估了使用人血浆提取物的代谢分析在代谢分析中的可行性。结果表明,成功检测270代谢物,表明我们平台的潜力,以产生更高的代谢物覆盖。此外,稀释性完整性分析证明了使用Ce-Hrms的代谢物分析的定量能力,尽管在代谢物33的情况下观察到饱和度或基质效应的存在。本研究表明,我们的平台对生物学研究和临床生物标志物筛选的血浆大规模代谢分析具有很大的潜力。

著录项

  • 来源
    《Analytical chemistry》 |2019年第2期|共7页
  • 作者单位

    Human Metabolome Technol Inc 246-2 Mizukami Tsuruoka Yamagata 9970052 Japan;

    Human Metabolome Technol Inc 246-2 Mizukami Tsuruoka Yamagata 9970052 Japan;

    Human Metabolome Technol Inc 246-2 Mizukami Tsuruoka Yamagata 9970052 Japan;

    Human Metabolome Technol Inc 246-2 Mizukami Tsuruoka Yamagata 9970052 Japan;

    Keio Univ Inst Adv Biosci 246-2 Mizukami Tsuruoka Yamagata 9970052 Japan;

    Keio Univ Inst Adv Biosci 246-2 Mizukami Tsuruoka Yamagata 9970052 Japan;

    Human Metabolome Technol Inc 246-2 Mizukami Tsuruoka Yamagata 9970052 Japan;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 分析化学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号