Dextran-Coated Cerium Oxide Nanoparticles: A Computed Tomography Contrast Agent for Imaging the Gastrointestinal Tract and Inflammatory Bowel Disease

机译:涂有葡聚糖氧化铈纳米颗粒:用于成像胃肠道和炎症性肠病的计算机断层摄影造影剂

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Computed tomography (CT) is an X-ray-based medical imaging technique commonly used for noninvasive gastrointestinal tract (GIT) imaging. Iodine- and barium-based CT contrast agents are used in the clinic for GIT imaging; however, inflammatory bowel disease (IBD) imaging is challenging since iodinated and barium-based CT agents are not specific for sites of inflammation. Cerium oxide nanoparticles (CeNP) can produce strong X-ray attenuation due to cerium’s k-edge at 40.4 keV but have not yet been explored for CT imaging. In addition, we hypothesized that the use of dextran as a coating material on cerium oxide nanoparticles would encourage accumulation in IBD inflammation sites in a similar fashion to other inflammatory diseases. In this study, therefore, we sought to develop a CT contrast agent, i.e. , dextran-coated cerium oxide nanoparticles (Dex-CeNP) for GIT imaging with IBD. We synthesized Dex-CeNP, characterized them using various analytical tools, and examined their in vitro biocompatibility, CT contrast generation, and protective effect against oxidative stress. In vivo CT imaging was done with both healthy mice and a dextran sodium sulfate induced colitis mouse model. Dex-CeNP’s CT contrast generation and accumulation in inflammation sites were compared with iopamidol, an FDA approved CT contrast agent. Dex-CeNP was found to be protective against oxidative damage. Dex-CeNP produced strong CT contrast and accumulated in the colitis area of large intestines. In addition, >97% of oral doses were cleared from the body within 24 h. Therefore, Dex-CeNP can be used as a potential CT contrast agent for imaging GIT with IBD while protecting against oxidative damage.
机译:计算机断层扫描(CT)是一种基于X射线的医学成像技术,通常用于非侵入性胃肠道(Git)成像。基于碘和基于钡的CT造影剂用于Git成像的诊所;然而,由于碘化的和基于钡的CT试剂对炎症部位不具体,因此炎症性肠病(IBD)成像是挑战性的。氧化铈纳米颗粒(CENP)可以产生强烈的X射线衰减,因为铈的K缘为40.4keV,但尚未探索CT成像。此外,我们假设使用葡聚糖作为氧化铈纳米颗粒上的涂料将促进IBD炎症位点的积累以类似的方式与其他炎症疾病。因此,在这项研究中,我们寻求开发CT造影剂, 97%的口服剂量从体内从24小时内清除。因此,DEX-CENP可以用作具有IBD的潜在CT造影剂,同时保护氧化损伤。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号