首页> 外文期刊>Anesthesia and Analgesia: Journal of the International Anesthesia Research Society >The influence of head and neck position on the oropharyngeal leak pressure and cuff position of three supraglottic airway devices.
【24h】

The influence of head and neck position on the oropharyngeal leak pressure and cuff position of three supraglottic airway devices.

机译:头颈部位置对三种声门上气道装置的口咽泄漏压力和袖带位置的影响。

获取原文
获取原文并翻译 | 示例
       

摘要

BACKGROUND: With supraglottic airway devices, such as the laryngeal tube suction (LTS), ProSeal laryngeal mask airway (PLMA) and Cobra perilaryngeal airway (CobraPLA), oropharyngeal leak pressure or cuff position may vary according to changes in the position of the head and neck. We evaluated oropharyngeal leak pressure and cuff pressure of the PLMA, LTS, and CobraPLA in different head and neck positions. METHODS: One-hundred-thirty-nine patients (aged 18-70 yr) scheduled for minor surgical procedures were randomly allocated to one of the supraglottic airway devices. Oropharyngeal leak pressure and cuff pressure were evaluated in four head and neck positions: neutral, 45 degrees of flexion, 45 degrees of extension, and 45 degrees of right rotation. Adverse events (i.e., difficulty in ventilation or gastric insufflation) were assessed during the study. RESULTS: Leak pressures of the PLMA were lowest in the extension (18.5 vs 23.9 and 26.8 cm H(2)O of LTS and CobraPLA, respectively; P < 0.001) and in therotation position (25.0 vs 29.4 and 28.5 cm H(2)O of LTS and CobraPLA, respectively; P < 0.005). With the CobraPLA, gastric insufflations occurred before the oropharyngeal leak in 37 of 45 patients. There were ventilatory difficulties in seven patients with LTS after neck flexion, which required tracheal intubation. CONCLUSIONS: The PLMA showed significantly lower oropharyngeal leak pressures than did the LTS or CobraPLA in the neck extension and rotation positions. Caution is warranted when changing the position of the head and neck when using the Cobra-PLA or LTS as gastric insufflation or ventilatory difficulty may occur.
机译:背景:对于声门上气道设备,例如喉管吸引(LTS),ProSeal喉罩气道(PLMA)和眼镜蛇周围喉气道(CobraPLA),口咽泄漏压力或袖带位置可能会根据头部和头部位置的变化而变化颈部。我们评估了在不同头颈部位置的PLMA,LTS和CobraPLA的口咽泄漏压力和袖带压力。方法:139例计划进行小手术的患者(年龄18-70岁)被随机分配到一种声门上气道装置。在四个头部和颈部位置评估了口咽泄漏压力和袖带压力:中立,弯曲45度,伸展45度和右旋45度。在研究过程中评估了不良事件(即通气困难或胃吹气困难)。结果:在延展期(分别为LTS和CobraPLA的扩展区(分别为18.5 vs 23.9和26.8 cm H(2)O),PLMA的最低压力; P <0.001)和旋转位置(25.0 vs 29.4和28.5 cm H(2))最低LTS和CobraPLA分别为O; P <0.005)。使用CobraPLA,在45例患者中有37例在口咽泄漏之前发生了胃吹气。颈部屈曲后7例LTS患者存在通气困难,需要气管插管。结论:在颈部伸展和旋转位置,PLMA的口咽泄漏压力明显低于LTS或CobraPLA。当使用Cobra-PLA或LTS时,改变头和颈部的位置时应格外小心,因为可能会发生胃吹气或通气困难。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号