首页> 外文期刊>Chemical Engineering Science >Current density distributions in polymer electrolyte fuel cells: A tool for characterisation of gas distribution in the cell and its state of health
【24h】

Current density distributions in polymer electrolyte fuel cells: A tool for characterisation of gas distribution in the cell and its state of health

机译:聚合物电解质燃料电池中的电流密度分布:一种用于表征细胞气体分布的工具及其健康状况

获取原文
获取原文并翻译 | 示例
           

摘要

Distributions of current density (cd) in a 100 cm(2) single polymer fuel cell have been measured, leading to a 12 x 12 data array. For a freshly matured MEA, the dimensionless distributions have been shown to be of moderate uniformity, whatever the cell current, with average deviations of the dimensionless cd in the range 0.16-0.25 (i.e. cd measured deviated from 16 to 25% from the expected value). More thorough examination of the data acquired showed that the non-uniformity is likely due to maldistribution of the gas in the 23 parallel channels of the multiple serpentine pattern of the commercial bipolar plates. For the sake of comparison, the MEA - including the two GDL was submitted to ageing with a standard cycling protocol (FC_DLC) emulating transportation conditions for 500 h. Characterisation of the cell state of health afterwards revealed visible degradation of the GDL, whereas the catalytic layer and the membrane were little affected. In the aged cell, distributions were shown to be far more non-uniform, with deviations ranging from 0.30 to 0.50: the current distributions were then depending on the cell current density. Presumably, due to the GDL ageing, liquid water produced at high cd, could not be removed efficiently, resulting in very low cd's near the outlet. (C) 2018 Elsevier Ltd. All rights reserved.
机译:已经测量了100cm(2)单个聚合物燃料电池中的电流密度(CD)的分布,导致12×12数据阵列。对于新成熟的MEA,无维分布已被证明具有中等的均匀性,无论电池电流如何,无量纲CD的平均偏差在0.16-0.25的范围内(即测量的CD从预期值偏离16%至25%。 )。更全面地检查所获取的数据显示,不均匀性可能是由于商业双极板的多个蛇纹石图案的23平行通道中的气体中的恶性。为了比较,将MEA - 包括两种GDL的衰老用标准循环方案(FC_DLC)进行500小时的运输条件。后者的细胞状态的表征显示出GDL的可见解降解,而催化层和膜很少受到影响。在老年的细胞中,分布显示得更不均匀,偏差范围为0.30至0.50:当前分布是根据电池电流密度的。据推测,由于GDL老化,在高CD中产生的液态水不能有效地除去,导致在出口附近非常低的CD。 (c)2018年elestvier有限公司保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号