首页> 外文期刊>Biosensors & Bioelectronics: The International Journal for the Professional Involved with Research, Technology and Applications of Biosensers and Related Devices >Electrochemical immunosensor for CDH22 biomarker based on benzaldehyde substituted poly(phosphazene) modified disposable ITO electrode: A new fabrication strategy for biosensors
【24h】

Electrochemical immunosensor for CDH22 biomarker based on benzaldehyde substituted poly(phosphazene) modified disposable ITO electrode: A new fabrication strategy for biosensors

机译:基于苯甲醛的CDH22生物标志物的电化学免疫传感器基于苯甲醛取代的聚(磷腈)改性一次性ITO电极:生物传感器的新制造策略

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

A novel label-free impedimetric immunosensor was fabricated for rapid, selective and sensitive detection and quantification of Cadherin-like protein 22 (CDH22), a cancer marker, in human serum by using easy and quickly prepared disposable ITO immunoelectrode. cancer marker, in human serum by using easy and quickly prepared disposable ITO immunoelectrode. The biosensing approach implied the use of ITO electrode coated with poly (phosphazene) polymer including benzaldehyde groups attached with CDH22 antibody and CDH22 antigens. Benzaldehyde side groups containing poly(phosphazene) film coated disposable ITO electrode were utilized as an immunosensing platform and anti-CDH22 antibodies bound to aldehyde groups of benzaldehyde substituted poly(phosphazene) (P-PHP) covalently. The immunosensor modification steps and affinity interaction between anti-CDH22 antibodies and CDH22 antigens were observed by EIS and CV in the presence of the redox couple. Furthermore, antibody immobilization was followed via FTIR and Raman spectroscopy. The morphological analyses of the suggested immunosensor during the fabrication steps were carried out with SEM and AFM monitoring. All the experimental parameters affecting the construction of the immunoelectrodes were optimized. The fabricated immunosensor exhibited an excellent working performance with a wide detection linear range (0.015-2.9 pg/mL) and low limit of detection (4.4 fg/mL). Moreover, the proposed immunosensor had great reproducibility, repeatability and long-term stability. Additionally, the fabricated immunosensor was successfully used in the quantification of CDH22 in human serum without any pretreatment.
机译:通过使用易于和快速制备的一次性ITO免疫电极,制备一种新的无标记的无阻抗免疫传感器,用于快速,选择性和敏感的蛋白质22(CDH22),癌症标志物,癌症标志物,癌症标志物。癌症标记,在人血清中使用易于制备的一次性ITO免疫电极。生物传感方法暗示使用涂有聚(磷腈)聚合物的ITO电极,包括用CDH22抗体和CDH22抗原连接的苯甲醛基团。含有聚(磷腈)薄膜涂膜的苯甲醛侧组用作共价与苯甲醛取代的聚(P-PHP)的醛基结合的免疫抑制平台和抗CDH22抗体。在氧化还原耦合的存在下,通过EIS和CV观察抗CDH22抗体和CDH22抗原之间的免疫传感器改性步骤和亲和相互作用。此外,通过FTIR和拉曼光谱洗脱抗体固定化。用SEM和AFM监测进行了在制造步骤期间建议的免疫传感器的形态学分析。优化影响免疫电极结构的所有实验参数。制造的免疫传感器具有优异的工作性能,具有宽检测线性范围(0.015-2.9pg / ml)和低检测限(4.4 fg / ml)。此外,所提出的免疫传感器具有很大的可重复性,可重复性和长期稳定性。另外,在没有预处理的情况下成功地用于在人血清中的量化CDH22的定量中成功使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号