首页> 外文期刊>American Journal of Infection Control >Improving central venous catheter insertion documentation to facilitate electronic surveillance of bundle compliance
【24h】

Improving central venous catheter insertion documentation to facilitate electronic surveillance of bundle compliance

机译:改进中央静脉导管插入文档,以促进对束顺应性的电子监视

获取原文
获取原文并翻译 | 示例
           

摘要

We developed an electronic surveillance system and modified electronic medical record and documentation practices to allow automated tracking of the central line bundle documentation with the insertion of central venous catheters. Despite significant improvements in documented use of the central line bundle in >80% of insertions, our central lineassociated bloodstream infection rate remained unchanged, suggesting the need to further improve compliance toward a goal of 100% of central line insertions, as well as training and education on proper line maintenance for catheters that are medically required for prolonged periods.
机译:我们开发了一种电子监视系统,并修改了电子病历和文件编制惯例,以允许在插入中央静脉导管的情况下自动跟踪中央线束文件。尽管在超过80%的插入中使用中心线束的文献记载有了显着改善,但我们与中心线相关的血液感染率仍保持不变,这表明有必要进一步提高对实现中心线插入100%的目标的依从性,并进行培训和对长期需要医疗的导管进行适当的管线维护方面的教育。