首页> 外文期刊>電子情報通信学会技術研究報告. 環境電磁工学. Electromagnetic Compatibility >Observation results of lightning surge current induced at AC mains line for access network equipment installed outdoors, and a lightning surge immunity test
【24h】

Observation results of lightning surge current induced at AC mains line for access network equipment installed outdoors, and a lightning surge immunity test

机译:AC电源线诱导通路电流电流电流接入网络设备的观察结果,以及闪电浪涌免疫检验

获取原文
获取原文并翻译 | 示例
           

摘要

As access network equipment installed outdoors has increased in performance and decreased in power, the likelihood of lightning surges induced in the access system has also increased. Power unit malfunctions occur frequently due to lightning surge current induced on the AC mains line. We observed the lightning surge current and the waveform characteristics, whose half time values are longer than existing recommendations, and the occurrence probability, which is 30 times greater than on telecommunication lines. Based on the observation results, this paper proposes a new lightning surge immunity test for access network systems.
机译:由于安装的接入网络设备的性能增加并且功率下降,所接入系统中引起的雷电浪涌的可能性也增加了。 由于在交流电源线上引起的闪电浪涌电流,功率单元发生故障频繁发生。 我们观察到闪电浪涌电流和波形特征,其半时间值比现有的建议长,并且发生概率,这比电信线大于30倍。 基于观察结果,本文提出了用于接入网络系统的新型闪电浪涌抗扰度测试。