Surface Tension Measurement for a New Low-GWP Refrigerant HFO-1123 by a Differential Capillary Rise Method

机译:新的低GWP制冷剂HFO-1123的表面张力测量通过差分毛细管升高方法

获取原文
获取原文并翻译 | 示例
           

摘要

By a differential capillary rise method, the surface tension was measured for a new candidate of low GWP refrigerant HFO-1123.16 points of surface tension data with a propagated uncertainty of approximately ±0.22 mNm~(-1) are presented in this paper. Based on the measured data, a Van der Waals type empirical correlation was proposed for HFO-1123: σ=61.02 (1-T/T_(crit)~(1.30) [mN m~(-1)], where T_(crit) is a critical temperature of 331.7 K measured by Higashi and Akasaka. This empirical correlation agrees with the measured surface tension data at temperatures from 267 K to 304 K.
机译:通过差分毛细管升高方法,本文提出了对低GWP制冷剂HFO-1123.16的新候选物的新候选物的新候选物测量了表面张力数据。 基于测量数据,提出了用于HFO-1123:σ= 61.02(1-T / T_(CRIT)〜(1.30)[MN m〜(-1)]的范德瓦尔斯型经验相关性,其中T_(CRIT )是由Higashi和Akasaka测量的331.7 k的临界温度。该实证相关性与测量的表面张力数据在267k至304k的温度下。