Comparison and repeatability of keratometric and corneal power measurements obtained by Orbscan II, Pentacam, and Galilei corneal tomography systems

机译:通过Orbscan II,Pentacam和Galilei角膜层析成像系统获得的角膜屈光度和角膜屈光度测量值的比较和可重复性

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Purpose: To assess the repeatability and comparability of corneal power and central corneal thickness (CCT) measurements obtained using Orbscan II (Bausch & Lomb), Pentacam (Oculus), and Galilei (Ziemer) tomographers. Design: Prospective, comparative study. Methods: setting: Departments of Ophthalmology, University of Auckland and Auckland District Health Board, Auckland, New Zealand. study population: Thirty eyes of 30 healthy participants. observations. CCT and corneal power measured using Orbscan II, Pentacam, and Galilei tomography. main outcome measures: Degree of agreement in and repeatability of CCT and corneal power measures. Results: Orbscan II measured significantly lower CCT compared with Pentacam (20 μm; P <.0005) and Galilei (18 μm; P <.0005). The Orbscan II had wide limits of agreement when compared with both the Galilei (-11 to 47 μm) and Pentacam (-88 to 47 μm). For each device, the intraclass correlation coefficient for CCT was higher than 0.9. The coefficient of variation ranged from 0.33% to 0.93%. There was no significant difference in mean steep keratometry or mean flat keratometry between instrument pairs. However, there was poor agreement in flat keratometry and steep keratometry obtained by Orbscan II compared with those obtained by the Galilei and Pentacam. Conclusions: The keratometry and pachymetry measurements obtained by Orbscan II, Pentcam, and Galilei tomographers were sufficiently disparate that the 3 devices could not be considered equivalent. All 3 devices demonstrated a high level of repeatability, although the Galilei exhibited the best repeatability.
机译:目的:评估使用Orbscan II(Bausch&Lomb),Pentacam(Oculus)和Galilei(Ziemer)断层扫描仪获得的角膜屈光力和中央角膜厚度(CCT)测量值的可重复性和可比性。设计:前瞻性比较研究。方法:地点:奥克兰大学眼科和新西兰奥克兰市奥克兰区卫生局。研究人群:30名健康参与者的30眼。观察。使用Orbscan II,Pentacam和Galilei层析成像技术测量CCT和角膜屈光力。主要结果指标:CCT和角膜屈光度指标的一致性程度和可重复性。结果:与Pentacam(20μm; P <.0005)和Galilei(18μm; P <.0005)相比,Orbscan II的CCT显着降低。与Galilei(-11至47μm)和Pentacam(-88至47μm)相比,Orbscan II具有广泛的一致性限制。对于每个设备,CCT的类内相关系数均高于0.9。变异系数为0.33%至0.93%。仪器对之间的平均陡度角膜曲率或平均平面角膜曲率没有显着差异。但是,与由Galilei和Pentacam获得的结果相比,由Orbscan II获得的平坦角膜测定法和陡峭角膜测定法的一致性差。结论:Orbscan II,Pentcam和Galilei断层扫描仪获得的角膜曲率和测厚法测量值相差悬殊,因此不能认为这3种设备是等效的。尽管伽利略展示了最好的可重复性,但所有这三个设备都显示出高水平的可重复性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号