...
首页> 外文期刊>American Journal of Veterinary Research >Methods and reliability of echocardiographic assessment of left atrial size and mechanical function in horses
【24h】

Methods and reliability of echocardiographic assessment of left atrial size and mechanical function in horses

机译:超声心动图评估马左心房大小和机械功能的方法和可靠性

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Objective-To assess the feasibility, describe the techniques, and determine the reliability of transthoracic echocardiography for characterization of left atrial (LA) size and LA mechanical function in horses. Animals-6 healthy adult horses. Procedures-Repeated echocardiographic examinations were performed independently by 2 observers in standing, unsedated horses by use of 2-dimensional echocardiography, pulsed-wave flow Doppler, and tissue Doppler imaging (TDI) techniques. Test reliability was determined by estimating measurement variability, within-day interobserver variability, and between-day inter- and intraobserver variability of all echocardiographic variables. Variability was expressed as the coefficient of variation (CV) and the absolute value below which the difference between 2 measurements will lie with 95% probability. Results-Most echocardiographic variables of LA size had low overall variability (CV, < 15%). Among the 2-dimensional indices of LA mechanical function, area-based and volume-based ejection phase indices had moderate between-day variability (CV usually < 25%). Transmitral Doppler flow indices were characterized by low to high between-day variability (CV, 6% to 35%). The TDI wall motion velocities had high between-day variability (CV, > 25%), whereas most TDI-derived time intervals had low variability (CV, < 15%). Conclusions and Clinical Relevance-LA size and mechanical function can be reliably assessed in standing, unsedated horses by use of 2-dimensional echocardiography, transmitral blood flow velocity profiles, and analyses of LA wall motion by use of TDI. These results may provide useful recommendations for echocardiographic assessment of LA size and function in horses.
机译:目的-评估可行性,描述技术,并确定经胸超声心动图对马的左心房(LA)大小和LA机械功能进行表征的可靠性。动物6个健康的成年马。程序重复的超声心动图检查由2位观察者在站立的未镇静的马中使用二维超声心动图,脉冲波多普勒和组织多普勒成像(TDI)技术独立进行。通过评估所有超声心动图变量的测量变异性,一天之内的观察者间变异性以及一天之内和观察者之间的变异性来确定测试的可靠性。变异性表示为变异系数(CV)和绝对值,在该绝对值以下,两次测量之间的差值为95%。结果-大多数LA大小的超声心动图变量总体变异性较低(CV,<15%)。在洛杉矶力学功能的二维指标中,基于面积和基于体积的射血期指标具有中等的日间波动性(CV通常<25%)。透射多普勒血流指数的特点是日间波动性低到高(CV,6%到35%)。 TDI壁运动速度具有较高的日间变异性(CV,> 25%),而大多数TDI派生的时间间隔具有较低的变异性(CV,<15%)。结论和临床相关性可以通过使用二维超声心动图,透射血流速度分布图以及使用TDI分析LA壁运动来可靠地评估站立的,未镇静的马的LA大小和机械功能。这些结果可能为超声心动图评估马的LA大小和功能提供有用的建议。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号