Objective-To determine appropriate intraocular lens (100 implant strength to approximate emmetropia in horses.Sample Population-16 enucleated globes and 4 adult horses.Procedures-Lens diameter of 10 enucleated globes was measured. Results were used to determine the appropriate-sized IOL implant for insertion in 6 enucleated globes and 4 eyes of adult horses. Streak retinoscopy and ocular ultrasonography were performed before and after insertion of 30-diopter (D) IOL implants (enucleated globes) and insertion of 25-D IOL implants (adult horses).Results-In enucleated globes, mean +/- SD lens diameter was 20.14 +/- 0.75 mm. Preoperative and postoperative refractive state of enucleated globes with 30-D IOL implants was -0.46 +/- 1.03 D and -2.47 +/- 1.03 D, respectively; preoperative and postoperative difference in refraction was 2.96 +/- 0.84 D. Preoperative anterior chamber (AC) depth, crystalline lens thickness (CLT), and axial globe length (AxL) were 712 +/- 0.82 mm, 11.32 +/- 0.81 mm, and 40.52 +/- 1.26 mm, respectively; postoperative AC depth was 10.76 +/- 1.16 mm. Mean ratio of preoperative to postoperative AC depth was 0.68. In eyes receiving 25-D IOL implants, preoperative and postoperative mean refractive error was 0.08 0.68 D and -3.94 +/- 1.88 D, respectively. Preoperative AC depth, CLT, and AxL were 6.36 +/- 0.22 mm, 10.92 +/- 1.92 mm, and 38.64 +/- 2.59 mm, respectively. Postoperative AC depth was 8.99 +/- 1.68 mm. Mean ratio of preoperative to postoperative AC depth was 0.73.Conclusions and Clinical Relevance-Insertion of 30-D (enucleated globes) and 25-D IOL implants (adult horses) resulted in overcorrection of refractive error. (Am J Vet Res 2010;71:809-816)
机译:目的-确定合适的人工晶状体(马的植入强度为100,近似正视眼。样本人口16个去核的球体和4只成年马的样本-测量10个去核的球体的透镜直径。结果用于确定适当大小的IOL植入物分别在插入30屈光度(D)IOL植入物(去核球镜)和插入25-D IOL植入物(成年马)之前和之后进行条纹视网膜检影和眼部超声检查,以在成年马的6个去核球镜和4眼中插入。结果:在摘除眼球的眼镜中,平均+/- SD镜片直径为20.14 +/- 0.75毫米;装有30-D IOL植入物的摘除眼球的术前和术后屈光状态为-0.46 +/- 1.03 D和-2.47 +/- 1.03分别为D;术前和术后屈光差为2.96 +/- 0.84 D.术前前房(AC)深度,晶状体厚度(CLT)和轴向球体长度(AxL)为712 +/- 0.82 mm,11.32 + /-0.81毫米,和40.52 +/- 1.26毫米;术后AC深度为10.76 +/- 1.16 mm。术前与术后AC深度的平均比值为0.68。在接受25-D IOL植入物的眼睛中,术前和术后平均屈光不正分别为0.08 0.68 D和-3.94 +/- 1.88D。术前AC深度,CLT和AxL分别为6.36 +/- 0.22 mm,10.92 +/- 1.92 mm和38.64 +/- 2.59 mm。术后AC深度为8.99 +/- 1.68 mm。术前与术后AC深度的平均比率为0.73。结论和临床相关性-插入30-D(摘除眼球)和25-D IOL植入物(成年马)会导致屈光不正的矫正。 (Am J Vet Res 2010; 71:809-816)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号