首页> 外文期刊>American journal of therapeutics >The average stent length is longer and the average stent diameter is shorter in patients with drug-eluting stents versus bare-metal stents during percutaneous coronary intervention.
【24h】

The average stent length is longer and the average stent diameter is shorter in patients with drug-eluting stents versus bare-metal stents during percutaneous coronary intervention.

机译:在经皮冠状动脉介入治疗期间,药物洗脱支架相对于裸金属支架的平均支架长度更长,平均支架直径更短。

获取原文
获取原文并翻译 | 示例
           

摘要

Drug-eluting stents (DES) were inserted in 180 patients (270 stents), mean age 63 years, and bare-metal stents (BMS) were inserted in 191 patients (301 stents), mean age 63 years, during percutaneous coronary intervention. Baseline characteristics were similar for patients treated with DES or BMS. The average stent length was longer for DES (16.83 mm) versus BMS (15.45 mm) (P = 0.0026). The average stent diameter was shorter for DES (2.89 mm) versus BMS (3.00 mm) (P = 0.00027). In-hospital stent thrombosis occurred in one of 270 DES (0.4%) versus three3 of 301 BMS (1.0%) (P = not significant).
机译:在经皮冠状动脉介入治疗期间,将180例患者(270个支架)插入药物洗脱支架(DES),平均年龄63岁;平均年龄63岁的191例患者(301个支架)插入裸金属支架(BMS)。接受DES或BMS治疗的患者的基线特征相似。 DES(16.83 mm)的平均支架长度比BMS(15.45 mm)的更长(P = 0.0026)。 DES(2.89 mm)的平均支架直径短于BMS(3.00 mm)(P = 0.00027)。 270 DES中的一种发生在医院内支架内血栓形成(0.4%),而301 BMS中的三项发生(1.0%)(P =不显着)。