Reprocessing of spent nuclear fuel is now undertaken as a national program in Japan, but the generation of spent fuel is estimated to exceed the reprocessing capacity . Therefore, spent fuel must be stored. Development of a dry vault system for spent fuel utilizing natural convection cooling is now underway at IHI. The heat dissipation performance of the storage system has been studied using analytical and experimental methods. Conditions under which the maximum fuel temperature remains below the permissible value have been sought using a simple analytical model. A structural model for the surroundings of the canister, which is the sealed container for spent fuel, was provided to measure thermal performance. Thermal fields in the canister was also calculated, and compared with test results.
机译:现在正在作为日本的国家计划进行废弃的核燃料再处理,但估计废燃料的产生超过再处理能力。 因此,必须存储燃料。 在IHI正在进行利用自然对流冷却的废燃料的干穹系统的开发。 使用分析和实验方法研究了存储系统的散热性能。 使用简单的分析模型寻求最大燃料温度仍然低于允许值的条件。 提供了一种用于罐周围环境的结构模型,是用于花费燃料的密封容器,以测量热性能。 还计算了罐中的热场,并与测试结果进行了比较。