Reprocessing of spent nuclear fuel is now undertaken as a national program in Japan, but the generation of spent fuel is estimated to exceed the reprocessing capacity . Therefore, spent fuel must be stored. Development of a dry vault system for spent fuel utilizing natural convection cooling is now underway at IHI. The heat dissipation performance of the storage system has been studied using analytical and experimental methods. Conditions under which the maximum fuel temperature remains below the permissible value have been sought using a simple analytical model. A structural model for the surroundings of the canister, which is the sealed container for spent fuel, was provided to measure thermal performance. Thermal fields in the canister was also calculated, and compared with test results.
机译:现在,日本已将乏核燃料的后处理作为一项国家计划进行,但估计乏燃料的产生量将超过后处理能力。因此,必须存储乏燃料。 IHI目前正在开发利用自然对流冷却的乏燃料干式穹顶系统。已经使用分析和实验方法研究了存储系统的散热性能。已经使用简单的分析模型寻找了最高燃料温度保持在允许值以下的条件。提供了用于罐环境的结构模型,该罐是用于乏燃料的密封容器,用于测量热性能。还计算了罐中的热场,并将其与测试结果进行了比较。