首页> 外文期刊>鋼構造論文集 >鋼2主鈑桁橋横桁部における場所打ちPC床版の応力性状
【24h】

鋼2主鈑桁橋横桁部における場所打ちPC床版の応力性状

机译:放置的应力特性在钢部件的平板导向部分中击中了PC楼层版本

获取原文
获取原文并翻译 | 示例
           

摘要

Cast - in - place prestressed concrete slab is mainly adopted to 2- girder bridges with the aim of rationalization and labor-saving. However, it is reported that cracks sometimes occur near by rigid cross beams several months after construction because of concrete's creep and shrinkage under restraint from the rigid beams and vertical stiffeners. In recent years, it is reported that sunshine, is supposed to induce the deformation of PC slab, and it is one of the reason of cracks. In this paper, stress conditions and efficiencies of prestressing in PC slab are evaluated by finite element analysis. The results indicate that cast in place PC slab near cross beams should be designed reducing live load stress and recognizing range of temperature of slab by sunshine.
机译:铸造预应力混凝土板主要采用2梁桥,目的是合理化和省力。 然而,据报道,由于混凝土的蠕变和垂直加强筋限制,施工后几个月,裂缝有时会在施工后几个月内发生裂缝。 近年来,据报道,阳光应该诱导PC板的变形,这是裂缝的原因之一。 在本文中,通过有限元分析评估了PC板中预应力的应力条件和效率。 结果表明,在横梁附近的PC板上铸造的PC板应通过阳光降低现场负荷应力并识别平板的温度范围。