首页> 外文期刊>Journal of medical imaging and radiation oncology >Optimising the dosimetric quality and efficiency of post-prostatectomy radiotherapy: A planning study comparing the performance of volumetric-modulated arc therapy (VMAT) with an optimised seven-field intensity-modulated radiotherapy (IMRT) technique
【24h】

Optimising the dosimetric quality and efficiency of post-prostatectomy radiotherapy: A planning study comparing the performance of volumetric-modulated arc therapy (VMAT) with an optimised seven-field intensity-modulated radiotherapy (IMRT) technique

机译:优化后前列腺切除术放射治疗的剂量测量和效率:将体积调制弧治疗(VMAT)与优化的七场强度调制放射治疗(IMRT)技术进行比较的规划研究

获取原文
获取原文并翻译 | 示例
       

摘要

Purpose: The purpose of this study was to compare and evaluate radiotherapy treatment plans using volumetric modulated arc therapy (VMAT) and intensity modulated radiotherapy (IMRT) for post-prostatectomy radiotherapy. Methods and Materials: The quality of radiotherapy plans for 10 patients planned and treated with a seven-field IMRT technique for biochemical failure post-prostatectomy were subsequently compared with 10 prospectively planned single-arc VMAT plans using the same computed tomography data set and treatment planning software. Plans were analysed using parameters to assess for target volume coverage, dose to organs at risk (OAR), biological outcomes, dose conformity and homogeneity, as well as the total monitor units (MU), planning and treatment efficiency. Results: The mean results for the study population are reported for the purpose of comparison. For IMRT, the median dose to the planning target volume, V 95%and D95% was 71.1 Gy, 98.9% and 68.3 Gy compared with 71.2 Gy, 99.2% and 68.6 Gy for VMAT. There was no significant difference in the conformity index or homogeneity index. The VMAT plans achieved better sparing of the rectum and the left and right femora with a reduction in the median dose by 7.9, 6.3 and 3.6 Gy, respectively. The total number of monitor units (MU) was reduced by 24% and treatment delivery time by an estimated 3 min per fraction without a significant increase in planning requirements. Conclusions: VMAT can achieve post-prostatectomy radiotherapy plans of comparable quality to IMRT with the potential to reduce dose to OAR and improve the efficiency of treatment delivery.
机译:目的:本研究的目的是使用体积调制的电弧治疗(VMAT)和强度调制放射治疗(IMRT)进行比较和评估放射治疗计划,用于后前列腺切除术放射治疗。方法和材料:随后与前列腺切断术后前列腺切除术后前列腺切除术后前列腺衰竭的七场IMRT技术的10名患者进行放疗计划的质量。软件。使用参数进行分析计划,以评估目标体积覆盖,以风险(OAR),生物结果,剂量符合性和均匀性,以及总监测单位(MU),规划和治疗效率,以及治疗效率的参数。结果:报告了研究人群的平均结果是为了比较目的。对于IMRT,对计划目标体积的中位剂量为71.1Gy,98.9%和68.3 Gy,而VMAT的71.2%,99.2%和68.6 Gy。符合性指数或同质性指数没有显着差异。 VMAT计划分别达到了直肠和左右股骨的比例,分别减少了7.9,6.3和3.6Gy的中位剂量减少。监测单元(MU)的总数减少24%和治疗递送时间,每次分数估计3分钟,没有显着增加规划要求。结论:VMAT可以实现相当质量的前列腺切除术放射疗法计划,ICRT有可能降低剂量,提高治疗递送效率。

著录项

  • 来源
  • 作者单位

    Division of Radiation Oncology and Cancer Imaging Peter MacCallum Cancer Centre A'Beckett Street;

    Radiation Therapy Services Peter MacCallum Cancer Centre East Melbourne VIC Australia;

    Department of Physical Sciences Peter MacCallum Cancer Centre East Melbourne VIC Australia;

    Department of Physical Sciences Peter MacCallum Cancer Centre East Melbourne VIC Australia;

    Radiation Therapy Services Peter MacCallum Cancer Centre East Melbourne VIC Australia;

    Radiation Therapy Services Peter MacCallum Cancer Centre East Melbourne VIC Australia;

    Department of Physical Sciences Peter MacCallum Cancer Centre East Melbourne VIC Australia;

    Division of Radiation Oncology and Cancer Imaging Peter MacCallum Cancer Centre A'Beckett Street;

    Division of Radiation Oncology and Cancer Imaging Peter MacCallum Cancer Centre A'Beckett Street;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 放射医学;
  • 关键词

    Intensity-modulated radiotherapy (IMRT); Planning; Prostate; Radiation therapy; Volumetric-modulated arc therapy (VMAT);

    机译:强度调节放疗(IMRT);规划;前列腺;放射治疗;体积调制的电弧疗法(VMAT);