首页> 外文期刊>Diabetes technology & therapeutics >Detection of hypoglycemia with continuous interstitial and traditional blood glucose monitoring using the FreeStyle Navigator Continuous Glucose Monitoring System.
【24h】

Detection of hypoglycemia with continuous interstitial and traditional blood glucose monitoring using the FreeStyle Navigator Continuous Glucose Monitoring System.

机译:使用自由式导航仪连续葡萄糖监测系统检测连续间质性和传统血糖监测的低血糖。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: The objective of the analysis was to compare detection of hypoglycemic episodes (glucose <70 mg/dL lasting >15 min) with the FreeStyle Navigator Continuous Glucose Monitoring System (FSN-CGM) (Abbott Diabetes Care, Alameda, CA) alarms to detection with traditional finger stick testing at an average frequency of eight tests per day. METHODS: The performance of FSN-CGM alarms was evaluated in a clinic setting using 58 subjects with type 1 diabetes mellitus (T1DM) monitoring interstitial glucose concentration over a 5-day period compared to reference YSI measurements (instrument manufactured by YSI, Yellow Springs, OH) at 15-min intervals. Finger stick glucose testing was evaluated in the home environment with 91 subjects with TIDM monitoring with the blood glucose meter integrated into the FreeStyle Navigator (FSN-BG) over a 20-day period. The reference was FSN-CGM with results masked from the subjects. Blood glucose values <=85 mg/dL were considered the optimal treatment level to avoid or reverse hypoglycemia. RESULTS: With a threshold alarm setting of 85 mg/dL, 90.6% of hypoglycemic episodes were detected within +/- 30 min by FSN-CGM in the clinic study. When the alarm was activated, YSI glucose was <= 85 mg/dL 77.2% of the time. In the home environment, the average FSN-BG testing frequency was 7.9 tests per day. Hypoglycemia was verified within +/- 30 min by FSN-BG measurements <= 85 mg/dL at a rate of 27.5%. CONCLUSIONS: Even with a high rate of FSN-BG testing, hypoglycemia detected by FSN-CGM was verified by patients with T1DM very infrequently. A high rate of hypoglycemia detection with a moderate rate of unnecessary alarms can be attained using FSN-CGM.
机译:背景:分析的目的是使用自由式导航仪连续葡萄糖监测系统(FSN-CGM)(FSN-CGM)(雅培糖尿病护理,Alameda,CA)警报进行比较低血糖发作(葡萄糖<70mg / d1)的检测通过传统的手指杆测试,每天八次测试的平均频率进行检测。方法:使用58型糖尿病(T1DM)监测50型糖尿病(T1DM)监测50型糖尿病(T1DM)的诊所设置评估FSN-CGM报警的性能。与参考YSI测量相比,在5天的时间内监测间质葡萄糖浓度(YSI,黄色弹簧制造的仪器,哦)在15分钟的间隔。在家庭环境中评估了手指粘葡萄糖测试,其中91名受试者,血糖仪在20天内将血糖仪与Freestyle Navigator(FSN-BG)集成在一起。该参考文献是FSN-CGM,结果来自受试者掩盖的结果。血糖值<= 85mg / dl被认为是最佳的治疗水平,以避免或逆转低血糖症。结果:临床研究中FSN-CGM在+/- 30分钟内检测到85mg / dL的阈值报警设置,在+/- 30分钟内检测到90.6%的低血糖集。当警报激活时,YSI葡萄糖为<= 85mg / dl 77.2%的时间。在家庭环境中,平均FSN-BG测试频率为每天7.9次测试。通过FSN-BG测量速率为27.5%的速率,通过FSN-BG测量效果在+/- 30分钟内核实。结论:即使具有高速率的FSN-BG测试,患有T1DM的患者验证了FSN-CGM检测到的低血糖。可以使用FSN-CGM获得具有中等不必要报警速率的高血糖检测率高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号