首页> 外文期刊>Journal of Zoo and Wildlife Medicine >ACCURACY OF NONINVASIVE ANESTHETIC MONITORING IN THE ANESTHETIZED GIRAFFE (GIRAFFA CAMELOPARDALIS)
【24h】

ACCURACY OF NONINVASIVE ANESTHETIC MONITORING IN THE ANESTHETIZED GIRAFFE (GIRAFFA CAMELOPARDALIS)

机译:麻醉长颈鹿非侵入性麻醉监测的准确性(长颈鹿Camelopardalis)

获取原文
获取原文并翻译 | 示例

摘要

This study evaluated the accuracy of pulse oximetry, capnography, and oscillometric blood pressure during general anesthesia in giraffes (Giraffa camelopardalis). Thirty-two giraffes anesthetized for physiologic experiments were instrumented with a pulse oximeter transmittance probe positioned on the tongue and a capnograph sampling line placed at the oral end of the endotracheal tube. A human size 10 blood pressure cuff was placed around the base of the tail, and an indwelling arterial catheter in the auricular artery continuously measured blood pressure. Giraffes were intermittently ventilated using a Hudson demand valve throughout the procedures. Arterial blood for blood gas analysis was collected at multiple time points. Relationships between oxygen saturation as determined by pulse oximetry and arterial oxygen saturation, between arterial carbon dioxide partial pressure and end-tidal carbon dioxide, and between oscillometric pressure and invasive arterial blood pressure were assessed, and the accuracy of pulse oximetry, capnography, and oscillometric blood pressure monitoring evaluated using Bland-Altman analysis. All three noninvasive methods provided relatively poor estimates of the reference values. Receiver operating characteristic curve fitting was used to determine cut-off values for hypoxia, hypocapnia, hypercapnia, and hypotension for dichotomous decision-making. Applying these cut-off values, there was reasonable sensitivity for detection of hypocapnia, hypercapnia, and hypotension, but not for hypoxemia. Noninvasive anesthetic monitoring should be interpreted with caution in giraffes and, ideally, invasive monitoring should be employed.
机译:该研究评估了长颈鹿(Giraffa Camelopardalis)的全身麻醉期间脉搏血氧测定,谱系和振动血压的准确性。为生理实验麻醉的三十二个长颈鹿用脉搏血氧仪透射探针仪表,位于舌头上,并且置于气管内管的口腔末端的谱图采样线。将人尺寸10血压袖带放置在尾部的底部周围,并且在耳廓动脉中的留置动脉导管持续测量血压。长颈鹿在整个程序中使用Hudson需求阀门间歇性地通风。在多个时间点收集血液气体分析的动脉血。通过脉搏血氧血管氧饱和度确定的氧饱和度与动脉二氧化碳分压和末端潮汐二氧化碳的关系,评估了脉冲血管压力和侵袭动脉血压力的血管二氧化碳分级压力和血液压力和侵袭性动脉血压之间的关系,以及脉搏血管血管谱,CAPNARITACTY和示波器的精度使用Bland-Altman分析评估血压监测。所有三种非冒险方法提供了相对较差的参考值估计。接收器操作特性曲线配件用于确定二分决策的缺氧,缺钙,高曲线和低血压的截止值。应用这些截止值,对缺钙,高曲线和低血压的检测有合理的敏感性,但不适用于缺氧血症。非侵入性麻醉监测应在长颈鹿中谨慎解释,理想情况下,应采用侵入性监测。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号