We evaluated the paper by Maley et al. (2020) in this journal "Infrared cameras overestimate skin temperature during rewarming from cold Exposure" for the evidence provided in support of its title and conclusions. Several methodological issues were identified as well as issues with the data interpretation: 1: Only one camera was used but a conclusion was made for 'cameras' in general; 2: The camera accuracy (+/- 2 degrees C) is too low to do a meaningful comparison without using local reference values or an on-site calibrator with higher accuracy; 3: Thermistor measurements are taken as a gold standard while issues such as temperature gradients and taping are known; 4: Both methods are not compared at the same location and a natural, physiological, gradient may be present between their locations; 5. The impact of the sensor and tape on delays in the change of the underlying tissue temperature is not considered; 6: Only a single pixel was used for the analysis, which has been shown to be problematic.
机译:我们通过Maley等人评估了论文。 (2020)在本期刊中,“红外摄像机在从冷曝光中再次感到皮肤温度”,“对于支持其标题和结论的证据。确定了几种方法论问题以及数据解释的问题:1:仅使用一台相机,但一般为“摄像机”制定了结论; 2:相机精度(+/- 2摄氏度C)太低,无法使用本地参考值或具有更高精度的现场校准器的有意义的比较; 3:热敏电阻测量作为金标准,而温度梯度和胶带等问题是已知的; 4:在其位置之间不在相同的位置和自然,生理,梯度之间进行比较; 5.不考虑传感器和磁带在潜在组织温度变化时的延迟的影响; 6:仅使用单个像素进行分析,这已被证明是有问题的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号