PURPOSE: To compare the nitinol occlusion plug with standard stainless steel coils for the occlusion of moderate-size peripheral veins. MATERIALS AND METHODS: The nitinol plug is a braided multilayered vascular occlusion device filled with thrombogenic polyester fibers. It is self-expanding and can be recaptured into its 6-F introducing sheath for repositioning prior to detachment. Ten occlusion procedures were performed in five dogs from a retrograde transjugular venous approach. Five nitinol plugs (diameter: 7.4 mm +/- 0.5) were deployed in five femoropopliteal veins (diameter: 6.5 mm +/- 0.7; mean oversizing 14.6%). Two sequential Gianturco coils (diameter: 7.4 mm +/- 0.9) were deployed in the corresponding contralateral veins (diameter: 6.2 mm +/- 0.8; mean oversizing 19.6%). Follow-up venography was performed at 1 month, following which the animals were killed and the vessels were explanted. RESULTS: Time-to-occlusion was significantly shorter with the nitinol plug as compared to two Gianturco coils (4.2 minutes +/- 3.4 vs 25.6 minutes +/- 14.1, respectively [P < .03]). At 1 month all but one coil-doublet (80%) had recanalized or migrated, compared to only one nitinol occluder (20%, P < .04). Histopathologic examination of plug-occluded veins showed a uniform organized matrix and underlying intimal proliferative response. CONCLUSION: A single nitinol occluder resulted in significantly faster occlusion time and significantly lower recanalization or migration rate than two Gianturco coils, in moderate-size peripheral veins.
机译:目的:将Nitinol闭塞塞与标准不锈钢线圈进行比较,用于闭塞中等大小的外周静脉。材料和方法:Nitinol塞是填充有血栓形成聚酯纤维的编织多层血管闭塞装置。它是自膨胀的,可以在拆卸之前重新进入其6-F引入护套以进行重新定位。从逆行的外胚静脉法中以五只狗进行十种闭塞程序。五个股骨质血管静脉(直径:6.5mm +/- 0.7;平均大调14.6%)部署五个硝基醇塞(直径:7.4mm +/- 0.5)。在相应的对侧静脉中部署了两个顺序Gianturco卷(直径:7.4mm +/- 0.9)(直径:6.2mm +/- 0.8;平均超大19.6%)。随访静脉造影在1个月内进行,后面的动物被杀死并突出血管。结果:与两个Gianturco线圈相比在1个月内,除了一个Nitinol封堵器(20%,P <0.04)相比,均未重新定义或迁移,除了一个线圈 - 双重(80%)。塞子闭塞静脉的组织病理学检查显示均匀的组织基质和潜在的内膜增殖性反应。结论:中等尺寸外周静脉,单个硝基诺封闭剂导致比两种Gianturco线圈的再生化或迁移率明显更低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号