Determination of the cut-off prothrombin time to estimate plasma rivaroxaban overdose status

机译:抑制凝血酶原时间来估计血浆肢体氧化试剂过量状态的测定

获取原文
获取原文并翻译 | 示例

摘要

Laboratory monitoring of rivaroxaban (RIV) is required under certain conditions. Mass spectrometry and anti-factor Xa assays are the recommended methods, which may not be readily available. Prothrombin time (PT) is the most widely used and simple coagulation assay. To set the cutoff PT and international normalized ratio (INR) to estimate RIV overdose status. RIV-spiked pooled normal plasma was used. PT test was performed using a CA-7000 coagulometer and Thromborel S reagent. The precise measurement of RIV concentration at the cut-off PT was evaluated according to the Clinical and Laboratory Standard Institute (CLSI) EP12-A2 guideline. The RIV concentration at 275 ng/mL was analyzed using 40 replicates. Receiver operating characteristic (ROC) analysis was performed to determine the cutoff value for the determination of RIV potential overdose status. An imprecision estimation of PT was conducted with 220.00 ng/mL, 247.50 ng/mL, 261.25 ng/mL, 288.75 ng/mL, 302.50 ng/mL and 330.00 ng/mL concentrations of RIV in 60 replicates. According to the ROC analysis, the cutoff clotting times and INR values to determine the overdose status of RIV were 13.45 s and 1.39. With these values, there was a 92.6% probability that plasma samples with RIV concentration = 302.50 ng/mL yield consistent positive (potential overdose) results using our PT assay. PT with a reliable cutoff clotting time and INR can be used to determine the potential overdose status of RIV to facilitate the diagnosis and treatment by controlling the dose.
机译:在某些条件下需要对Rivaroxaban(RIV)的实验室监测。质谱和抗因子XA测定是推荐的方法,这可能不易获得。凝血酶原时间(Pt)是最广泛使用和简单的凝固测定。设置截止PT和国际归一化比率(INR)以估计RIV过量状态。使用RIV掺入的汇集正常血浆。使用Ca-7000凝血仪和Thromborel S试剂进行PT测试。根据临床和实验室标准研究所(CLSI)EP12-A2指南,评价截止PT的RIV浓度的精确测量。使用40重复分析275ng / ml的RIV浓度。进行接收器操作特征(ROC)分析以确定用于确定RIV电位过量状态的截止值。 Pt的不精确估计用220.00ng / ml,247.50ng / ml,261.25ng / ml,288.75ng / ml,302.50ng / ml和330.00ng / ml浓度的60重新重复。根据ROC分析,确定RIV的过量状态的截止凝血时间和INR值为13.45 s和1.39。通过这些值,存在具有RIV浓度= 302.50ng / ml的血浆样品的概率= 302.50ng / ml使用PT测定的结果一致阳性(潜在过量)结果。 PT具有可靠的截止凝血时间和INR可用于确定RIV的潜在过量状态,以促进通过控制剂量来诊断和治疗。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号