...
首页> 外文期刊>Journal of thrombosis and haemostasis: JTH >An international collaborative study to compare different von Willebrand factor glycoprotein Ib binding activity assays: the COMPASS‐VWF study
【24h】

An international collaborative study to compare different von Willebrand factor glycoprotein Ib binding activity assays: the COMPASS‐VWF study

机译:一种与不同的von Willebrand因子糖蛋白Ib结合活性测定进行比较的国际协同研究:Compass-VWF研究

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Essentials New VWF activity assays are increasingly used but information on their comparability is limited. This is an ISTH SSC‐organized study (expert labs, 5 countries) to compare all available assays. VWF activity by six assays correlated well with each other. The new assays show improved characteristics ‐ minor differences are noted. Summary Background Several new assays have become available to measure von Willebrand factor ( VWF ) activity. The new assays appear to have improved performance characteristics compared with the old reference standard, ristocetin cofactor activity ( VWF : RC o), but information is limited about how they compare with VWF : RC o and each other. Methods The von Willebrand factor Subcommittee of the International Society for Thrombosis and Haemostasis ( ISTH ) Scientific and Standardization Committee ( SSC ) designed a collaborative study involving expert laboratories from several countries to compare available tests with each other and with VWF : RC o. Eight laboratories from five countries were provided with blinded samples from normal healthy individuals and well‐characterized clinical cases. Laboratories measured VWF activity using all tests available to them; data from six laboratories, not affected by thawing during transportation, are included in this study. Results All tests correlated well with VWF : RC o activity ( r ‐values ranged from 0.963 to 0.989). Slightly steeper regression lines for VWF :Ab and VWF : GPI bM were clinically insignificant. The new assays showed improved performance characteristics. Of the commercially available assays, the VWF : GPI bR using the AcuStar system was the most sensitive and could reliably detect VWF activity below 1? IU ? dL ?1 . The lower limit of the measuring interval for the VWF : GPI bM and the VWF : GPI bR assays was in the 3–4 and 3–6? IU ? dL ?1 range, respectively. Inter‐laboratory variation was also improved for most new assays. Conclusion All VWF activity assays correlated well with each other and the VWF : RC o assay. The slight differences in characteristics found in the COMPASS ‐ VWF study will assist the VWF community in interpreting and comparing activity results.
机译:Essentials新的VWF活动测定越来越多地使用,但有关其可比性的信息是有限的。这是一项ISTH SSC组织的研究(专家实验室,5个国家),用于比较所有可用的测定。 VWF活动六个测定彼此相互关联。新的测定显示出改善的特性 - 注意到了微小的差异。摘要背景有几个新的测定可用于测量von Willebrand因子(VWF)活动。与旧的参考标准,Ristocetin Cofactor活动(VWF:RC O)相比,新测定似乎具有改进的性能特征,但信息有限于它们与VWF的比较:RC o和彼此。方法血栓形成和浩劫(ISTH)科学和标准化委员会(SSC)国际社会的von Willebrand因素小组委员会(SSC)旨在涉及来自几个国家的专家实验室的合作研究,以比较彼此的可用测试和VWF:RC o。来自五个国家的八个实验室从正常健康个体和临床病例的正常健康个体和特征性的临床病例提供了盲化样本。实验室使用所有测试的所有测试测量了VWF活动;来自运输过程中不受影响的六个实验室的数据包括在本研究中。结果所有测试都与VWF相关,RC O活动(R -Values范围为0.963至0.989)。 VWF略陡的回归线:AB和VWF:GPI BM在临床上微不足道。新的测定显示出改善的性能特征。在市售的测定中,VWF:GPI Br使用acustar系统是最敏感的,可以可靠地检测1以下的VWF活动? IU? dl?1。 VWF测量间隔的下限:GPI BM和VWF:GPI BR测定在3-4和3-6中? IU? DL?1范围分别。对于大多数新测定,还改善了实验室内变异。结论所有VWF活性测定相互关联,VWF:RC O测定。 Compass - VWF研究中发现的特征的轻微差异将帮助VWF群落解释和比较活动结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号