Abstract Nowadays there is a wide variety of surgical sutures available in the market. Surgical sutures have different sizes, structures, materials and coatings, whereas they are being used for various surgeries. The frictional performances of surgical sutures have been found to play a vital role in their functionality. The high friction force of surgical sutures in the suturing process may cause inflammation and pain to the person, leading to a longer recovery time, and the second trauma of soft or fragile tissue. Thus, the investigation into the frictional performance of surgical suture is essential. Despite the unquestionable fact, little is actually known on the friction performances of surgical suture-tissue due to the lack of appropriate test equipment. This study presents a new penetration friction apparatus (PFA) that allowed for the evaluation of the friction performances of various surgical needles and sutures during the suturing process, under different contact conditions. It considered the deformation of tissue and can realize the puncture force measurements of surgical needles as well as the friction force of surgical sutures. The developed PFA could accurately evaluate and understand the frictional behaviour of surgical suture-tissue in the simulating clinical conditions. The forces measured by the PFA showed the same trend as that reported in literatures. Graphical abstract Display Omitted ]]>
机译:摘要如今市场上有各种各样的手术缝线。手术缝合线具有不同的尺寸,结构,材料和涂料,而它们用于各种手术。发现手术缝合线的摩擦性能在其功能中起着至关重要的作用。缝合过程中手术缝合线的高摩擦力可能导致人的炎症和疼痛,导致较长的恢复时间,以及柔软或脆弱组织的第二个创伤。因此,对手术缝合线的摩擦性能进行调查至关重要。尽管毫无疑问的事实,但由于缺乏适当的测试设备,缺乏手术缝合线组织的摩擦性能很少。该研究呈现了一种新的渗透摩擦装置(PFA),其允许在缝合过程中评估各种外科针和缝合线的摩擦性能,在不同的接触条件下。它认为组织的变形,可以实现手术针的穿刺力测量以及手术缝合线的摩擦力。开发的PFA可以准确地评估和理解在模拟临床条件下手术缝合线组织的摩擦行为。 PFA测量的力显示出与文献中报告的相同趋势。省略图形抽象显示]]>

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号