首页> 外文期刊>American journal of contact dermatitis: official journal of the American Contact Dermatitis Society >Cross-reactivity among epoxy acrylates and bisphenol F epoxy resins in patients with bisphenol A epoxy resin sensitivity.
【24h】

Cross-reactivity among epoxy acrylates and bisphenol F epoxy resins in patients with bisphenol A epoxy resin sensitivity.

机译:对双酚A环氧树脂敏感的患者中环氧丙烯酸酯和双酚F环氧树脂之间的交叉反应性。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: The study's objective was 2-fold: first, to evaluate the potential cross-reactivity between Bis-A epoxy resins and epoxy acrylates and second, to study the cross reactivity between Bis-A epoxy resins and newer Bis-F epoxy resins in patients with allergic contact dermatitis to epoxy resins and had positive patch test to the standard epoxy resin based on bisphenol A. METHODS: Forty-one patients were patch tested to 23 chemicals including epoxy acrylates, Bis-A epoxy resins, and Bis-F epoxy resins, as well as reactive diluents and nonbisphenol epoxy resins. Questions concerning exposure to epoxy resins, occupational history, and problems with dental work were completed. RESULTS: All patients included in the study had positive reactions to the standard Bis-A epoxy resin. Twenty percent (8 of 41) of the patients reacted to at least one of the epoxy acrylates; the most common reaction was to Bis-GMA. Five of 8 patients who reacted to the epoxy acrylates had dental work, but only one patient had problems from her dental work. Six of 8 patients (75%) who reacted to epoxy resins and epoxy acrylates did not react to aliphatic acrylates. Thirty-two percent (13 of 41) reacted to tosylamide epoxy resin, and none reacted to triglycidyl isocyanurate resin. In addition, all patients (100%) had positive reactions to at least one of the Bis-F epoxy resins that were tested. CONCLUSIONS: Most patients with sensitivity to Bis-A epoxy resins do not cross-react with epoxy acrylates. Patients with positive patch test reactions to epoxy acrylates used in dentistry usually do not have symptoms from their dental work. To our knowledge, this is the largest series of patients with sensitivity to the standard Bis-A epoxy resin that have been patch tested with the more recently introduced Bis-F epoxy resins. There is significant cross-reactivity between Bis-A and Bis-F epoxy resins, which can be explained by their structural similarity.
机译:目的:该研究的目标是两个方面:首先,评估Bis-A环氧树脂与环氧丙烯酸酯之间的潜在交叉反应性;其次,研究Bis-A环氧树脂与较新的Bis-F环氧树脂之间的交叉反应性。对环氧树脂有过敏性接触性皮炎的患者,并且对基于双酚A的标准环氧树脂进行了斑贴试验。方法:对41名患者进行了23种化学药品的斑贴测试,包括丙烯酸环氧酯,Bis-A环氧树脂和Bis-F环氧树脂树脂,以及反应性稀释剂和非双酚环氧树脂。有关暴露于环氧树脂,职业病史以及牙科工作问题的问题已经完成。结果:所有纳入研究的患者对标准Bis-A环氧树脂都有阳性反应。 20%(41名中的8名)患者对至少一种环氧丙烯酸酯有反应;最常见的反应是对Bis-GMA的反应。对环氧丙烯酸酯有反应的8位患者中有5位有牙科工作,但只有1名患者因牙科工作而出现问题。对环氧树脂和环氧丙烯酸酯有反应的8名患者中有6名(75%)对脂族丙烯酸酯没有反应。 32%(41个中的13个)与甲苯磺酰胺环氧树脂反应,没有一个与三缩水甘油基异氰脲酸酯树脂反应。此外,所有患者(100%)对至少一种被测试的Bis-F环氧树脂有阳性反应。结论:大多数对Bis-A环氧树脂敏感的患者不会与环氧丙烯酸酯发生交叉反应。对牙科用环氧丙烯酸酯的斑贴试验反应阳性的患者通常没有牙科工作的症状。据我们所知,这是对标准Bis-A环氧树脂敏感的最大系列患者,这些患者已与最新推出的Bis-F环氧树脂进行了贴剂测试。 Bis-A和Bis-F环氧树脂之间存在明显的交叉反应性,这可以通过它们的结构相似性来解释。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号