首页> 外文期刊>Journal of radiological protection: Official journal of the Society for Radiological Protection >Diagnostic reference levels for common computed tomography (CT) examinations: results from the first Nigerian nationwide dose survey
【24h】

Diagnostic reference levels for common computed tomography (CT) examinations: results from the first Nigerian nationwide dose survey

机译:常见计算断层扫描(CT)考试的诊断参考水平:第一个尼日利亚全国剂量调查的结果

获取原文
获取原文并翻译 | 示例
       

摘要

Purpose. To explore doses from common adult computed tomography (CT) examinations and propose national diagnostic reference levels (nDRLs) for Nigeria. Materials and Methods. This retrospective study was approved by the Nnamdi Azikiwe University and University Teaching Hospital Institutional Review Boards (IRB: NAUTH/CS/66/Vol8/84) and involved dose surveys of adult CT examinations across the six geographical regions of Nigeria and Abuja from January 2016 to August 2017. Dose data of adult head, chest and abdomen/pelvis CT examinations were extracted from patient folders. The median, 75th and 25th percentile CT dose index volume (CTDIvol) and dose-length-product (DLP) were computed for each of these procedures. Effective doses (E) for these examinations were estimated using the k conversion factor as described in the ICRP publication 103 (E-DLP = k x DLP). Results. The proposed 75th percentile CTDIvol for head, chest, and abdomen/pelvis are 61 mGy, 17 mGy, and 20 mGy, respectively. The corresponding DLPs are 1310 mGy. cm, 735 mGy. cm, and 1486 mGy. cm respectively. The effective doses were 2.75 mSv (head), 10.29 mSv (chest), and 22.29 mSv (abdomen/pelvis). Conclusion. Findings demonstrate wide dose variations within and across centres in Nigeria. The results also show CTDIvol comparable to international standards, but considerably higher DLP and effective doses.
机译:目的。从共同成人计算断层扫描(CT)考试中探索患有尼日利亚的国家诊断参考水平(NDRLS)。材料和方法。该回顾性研究由Nnamdi Azikiwe大学和大学教学医院机构审查委员会(IRB:Nauth / CS / 66 / Vol8 / 84)批准,并于2016年1月从尼日利亚和阿布贾的六个地理区域进行成人CT考试剂量调查到2017年8月。从患者文件夹中提取成人头部,胸部和腹部/骨盆CT检查的剂量数据。计算中位,第75和第25百分位CT剂量指数体积(CTDIVOL)和剂量长度 - 产品(DLP)用于每个程序中的每一个。使用如ICRP公开103(E-DLP = K X DLP)中所述的K转换因子估计这些检查的有效剂量(e)。结果。提出的第75百分位CTDIVOL用于头部,胸部和腹部/骨盆,分别为61毫米,17吨和20米。相应的DLP是1310 MGY。 cm,735 mgy。 cm,1486 mgy。 CM分别。有效剂量为2.75msV(头部),10.29msv(胸部)和22.29msv(腹部/骨盆)。结论。调查结果表明尼日利亚内部内部和跨越中心的宽剂变化。结果还显示了与国际标准相当的CTDIVOL,但DLP和有效剂量相当。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号